El contenido no se encuentra disponible en el idioma seleccionado. Estamos trabajando continuamente para agregar más idiomas. Gracias por su apoyo.

Compute
Elastic Cloud Server
Huawei Cloud Flexus
Bare Metal Server
Auto Scaling
Image Management Service
Dedicated Host
FunctionGraph
Cloud Phone Host
Huawei Cloud EulerOS
Networking
Virtual Private Cloud
Elastic IP
Elastic Load Balance
NAT Gateway
Direct Connect
Virtual Private Network
VPC Endpoint
Cloud Connect
Enterprise Router
Enterprise Switch
Global Accelerator
Management & Governance
Cloud Eye
Identity and Access Management
Cloud Trace Service
Resource Formation Service
Tag Management Service
Log Tank Service
Config
OneAccess
Resource Access Manager
Simple Message Notification
Application Performance Management
Application Operations Management
Organizations
Optimization Advisor
IAM Identity Center
Cloud Operations Center
Resource Governance Center
Migration
Server Migration Service
Object Storage Migration Service
Cloud Data Migration
Migration Center
Cloud Ecosystem
KooGallery
Partner Center
User Support
My Account
Billing Center
Cost Center
Resource Center
Enterprise Management
Service Tickets
HUAWEI CLOUD (International) FAQs
ICP Filing
Support Plans
My Credentials
Customer Operation Capabilities
Partner Support Plans
Professional Services
Analytics
MapReduce Service
Data Lake Insight
CloudTable Service
Cloud Search Service
Data Lake Visualization
Data Ingestion Service
GaussDB(DWS)
DataArts Studio
Data Lake Factory
DataArts Lake Formation
IoT
IoT Device Access
Others
Product Pricing Details
System Permissions
Console Quick Start
Common FAQs
Instructions for Associating with a HUAWEI CLOUD Partner
Message Center
Security & Compliance
Security Technologies and Applications
Web Application Firewall
Host Security Service
Cloud Firewall
SecMaster
Anti-DDoS Service
Data Encryption Workshop
Database Security Service
Cloud Bastion Host
Data Security Center
Cloud Certificate Manager
Edge Security
Managed Threat Detection
Blockchain
Blockchain Service
Web3 Node Engine Service
Media Services
Media Processing Center
Video On Demand
Live
SparkRTC
MetaStudio
Storage
Object Storage Service
Elastic Volume Service
Cloud Backup and Recovery
Storage Disaster Recovery Service
Scalable File Service Turbo
Scalable File Service
Volume Backup Service
Cloud Server Backup Service
Data Express Service
Dedicated Distributed Storage Service
Containers
Cloud Container Engine
SoftWare Repository for Container
Application Service Mesh
Ubiquitous Cloud Native Service
Cloud Container Instance
Databases
Relational Database Service
Document Database Service
Data Admin Service
Data Replication Service
GeminiDB
GaussDB
Distributed Database Middleware
Database and Application Migration UGO
TaurusDB
Middleware
Distributed Cache Service
API Gateway
Distributed Message Service for Kafka
Distributed Message Service for RabbitMQ
Distributed Message Service for RocketMQ
Cloud Service Engine
Multi-Site High Availability Service
EventGrid
Dedicated Cloud
Dedicated Computing Cluster
Business Applications
Workspace
ROMA Connect
Message & SMS
Domain Name Service
Edge Data Center Management
Meeting
AI
Face Recognition Service
Graph Engine Service
Content Moderation
Image Recognition
Optical Character Recognition
ModelArts
ImageSearch
Conversational Bot Service
Speech Interaction Service
Huawei HiLens
Video Intelligent Analysis Service
Developer Tools
SDK Developer Guide
API Request Signing Guide
Terraform
Koo Command Line Interface
Content Delivery & Edge Computing
Content Delivery Network
Intelligent EdgeFabric
CloudPond
Intelligent EdgeCloud
Solutions
SAP Cloud
High Performance Computing
Developer Services
ServiceStage
CodeArts
CodeArts PerfTest
CodeArts Req
CodeArts Pipeline
CodeArts Build
CodeArts Deploy
CodeArts Artifact
CodeArts TestPlan
CodeArts Check
CodeArts Repo
Cloud Application Engine
MacroVerse aPaaS
KooMessage
KooPhone
KooDrive
Help Center/ MapReduce Service/ User Guide (Ankara Region)/ Alarm Reference/ ALM-27005 Database Connection Usage Exceeds the Threshold

ALM-27005 Database Connection Usage Exceeds the Threshold

Updated on 2024-11-29 GMT+08:00

Alarm Description

The system checks the database connection usage of the DBServer node every 30 seconds and compares the actual database connection usage with the threshold. This alarm is generated when the database connection usage exceeds the threshold for five consecutive times (configurable, five by default).

The trigger count is configurable. When the value is 1 and the data connections are no more than the threshold, the alarm is cleared. When the trigger count is greater than 1 and the data connections are no more than 90% of the threshold, the alarm is cleared.

Alarm Attributes

Alarm ID

Alarm Severity

Alarm Type

Service Type

Auto Cleared

27005

Critical (default threshold: 95%)

Major (The default threshold: 90%)

Quality of service

FusionInsight Manager

Yes

Alarm Parameters

Type

Parameter

Description

Location Information

Source

Specifies the cluster for which the alarm is generated.

ServiceName

Specifies the service for which the alarm is generated.

RoleName

Specifies the role for which the alarm is generated.

HostName

Specifies the host for which the alarm is generated.

Additional Information

Trigger condition

Specifies the alarm triggering condition.

Impact on the System

Upper-layer services may fail to connect to the DBService database, affecting services.

Possible Causes

  • There are too many database connections in use.
  • The maximum number of database connections is set improperly.
  • The alarm threshold or alarm trigger count is improperly configured.

Handling Procedure

Check whether there are too many database connections in use.

  1. On FusionInsight Manager, click DBService in the service list on the left. The DBService monitoring page is displayed.
  2. View the number of connections used by the database user, as shown in Figure 1. You can reduce the number of connections based on service requirements.

    Figure 1 Connections used by the database user

  3. Wait 2 minutes and check whether the alarm is cleared.

    • If yes, no further action is required.
    • If no, go to 4.

Check whether the maximum number of database connections is set properly.

  1. Log in to FusionInsight Manager, choose Cluster > Name of the desired cluster > Service > DBService, click Configuration and then All Configurations. Increase the maximum number of database connections allowed based on service requirements. After the modification, click Save. On the page that is displayed, click OK.

    Figure 2 Setting maximum database connections

  2. After changing the maximum number of database connections, restart DBService (do not restart its upper-layer services).

    Procedure: Log in to FusionInsight Manager, choose Cluster > Name of the desired cluster > Service > DBService. On the displayed page, click More > Restart Service in the upper right corner, enter the password of the current login user, and click OK. Do not select Restart upper-layer services. Click OK.

  3. Wait 2 minutes and check whether the alarm is automatically cleared.

    • If yes, no further action is required.
    • If no, go to 7.

Check whether the alarm threshold or alarm trigger count is properly configured.

  1. Log in to FusionInsight Manager and change the alarm threshold and alarm smoothing times based on the number of database connections. Click O&M and choose Alarm > Thresholds in the navigation pane on the left. On the displayed page, click the name of the desired cluster > DBService > Database > Database Connection Usage (DBServer). Click the pencil icon next to Trigger Count to change the value.

    NOTE:

    If the value of Trigger Count exceeds the threshold, the alarm is generated.

    Figure 3 Setting the alarm trigger count

    Click O&M, and choose Alarm > Thresholds in the navigation pane on the left. On the displayed page, click the name of the desired cluster > DBService > Database > Database Connection Usage (DBServer) in the list on the left. Click Modify in the Operation column. Modify the rule and click OK. The modification takes effect immediately.

    Figure 4 Configuring the alarm threshold

  2. Wait 2 minutes and check whether the alarm is automatically cleared.

    • If yes, no further action is required.
    • If no, go to 9.

Collect fault information.

  1. On FusionInsight Manager, choose O&M. In the navigation pane on the left, choose Log > Download.
  2. Expand the Service drop-down list, and select DBService for the target cluster.
  3. Specify Hosts for collecting logs, which is optional. By default, all hosts are selected.
  4. Click in the upper right corner, and set Start Date and End Date for log collection to 10 minutes ahead of and after the alarm generation time, respectively. Then, click Download.
  5. Contact O&M engineers and provide the collected logs.

Alarm Clearance

This alarm is automatically cleared after the fault is rectified.

Related Information

None.