ALM-14002 DataNode Disk Usage Exceeds the Threshold
Alarm Description
The system checks the DataNode disk usage every 30 seconds and compares the actual disk usage with the threshold. A default threshold range is provided for the DataNode disk usage. This alarm is generated when the DataNode disk usage exceeds the threshold.
To change the threshold, choose O&M > Alarm > Thresholds > Name of the desired cluster > HDFS.
If Trigger Count is 1, this alarm is cleared when the DataNode disk usage is less than or equal to the threshold. If Trigger Count is greater than 1, this alarm is cleared when the DataNode disk usage is less than or equal to 80% of the threshold.
Alarm Attributes
Alarm ID |
Alarm Severity |
Alarm Type |
Service Type |
Auto Cleared |
---|---|---|---|---|
14002 |
Critical (default threshold: 90%) Major (default threshold: 80%) |
Quality of service |
HDFS |
Yes |
Alarm Parameters
Type |
Parameter |
Description |
---|---|---|
Location Information |
Source |
Specifies the cluster for which the alarm was generated. |
ServiceName |
Specifies the service for which the alarm was generated. |
|
RoleName |
Specifies the role for which the alarm was generated. |
|
HostName |
Specifies the host for which the alarm was generated. |
|
Additional Information |
Trigger Condition |
Specifies the alarm triggering condition. |
Impact on the System
Insufficient disk space will impact data write to HDFS.
Possible Causes
- The disk space configured for the HDFS cluster is insufficient.
- Data skew occurs among DataNodes.
Handling Procedure
Check whether the cluster disk capacity is full.
- On FusionInsight Manager, choose O&M > Alarm > Alarms, and check whether the ALM-14001 HDFS Disk Usage Exceeds the Threshold alarm exists.
- Handle the alarm by following the instructions in ALM-14001 HDFS Disk Usage Exceeds the Threshold and check whether the alarm is cleared.
- Choose O&M > Alarm > Alarms and check whether the alarm is cleared.
- If yes, no further action is required.
- If no, go to 4.
Check the balance status of DataNodes.
- On FusionInsight Manager, choose Hosts. Check whether the number of DataNodes on each rack is almost the same. If the difference is large, adjust the racks to which DataNodes belong to ensure that the number of DataNodes on each rack is almost the same. Restart the HDFS service for the settings to take effect.
- Choose Cluster > Name of the desired cluster > Services > HDFS.
- In the Basic Information area, click NameNode(Active). The HDFS web UI is displayed.
By default, the admin user does not have the permissions to manage other components. If the page cannot be opened or the displayed content is incomplete when you access the native UI of a component due to insufficient permissions, you can manually create a user with the permissions to manage that component.
- In the Summary area of the HDFS web UI, check whether the value of Max is 10% greater than that of Median in DataNodes usages.
- Balance skewed data in the cluster. Log in to the MRSclient as user root. If the cluster is in normal mode, run the su - omm command to switch to user omm. Run the cd command to go to the client installation directory and run the source bigdata_env command. If the cluster uses the security mode, perform security authentication. Run kinit hdfs and enter the password as prompted. Obtain the password from the MRS cluster administrator.
- Run the following command to balance data distribution:
hdfs balancer -threshold 10
- Wait several minutes and check whether the alarm is cleared.
- If yes, no further action is required.
- If no, go to 11.
Collect the fault information.
- On FusionInsight Manager, choose O&M. In the navigation pane on the left, choose Log > Download.
- Expand the drop-down list next to the Service field. In the Services dialog box that is displayed, select HDFS for the target cluster.
- Click in the upper right corner, and set Start Date and End Date for log collection to 10 minutes ahead of and after the alarm generation time, respectively. Then, click Download.
- Contact O&M engineers and provide the collected logs.
Alarm Clearance
This alarm is automatically cleared after the fault is rectified.
Related Information
None.
Feedback
Was this page helpful?
Provide feedbackThank you very much for your feedback. We will continue working to improve the documentation.See the reply and handling status in My Cloud VOC.
For any further questions, feel free to contact us through the chatbot.