ALM-12083 Password of User ommdba Is About to Expire
Alarm Description
The system starts at 00:00 every day to check whether the password of user ommdba is about to expire every 8 hours. This alarm is generated if the password is about to expire no less than 15 days later.
This alarm is cleared when the expiration time of user ommdba password is reset and the user password status becomes normal.
Alarm Attributes
Alarm ID |
Alarm Severity |
Alarm Type |
Service Type |
Auto Cleared |
---|---|---|---|---|
12083 |
Minor |
Security |
FusionInsight Manager |
Yes |
Alarm Parameters
Type |
Parameter |
Description |
---|---|---|
Location Information |
Source |
Specifies the cluster or system for which the alarm is generated. |
ServiceName |
Specifies the service for which the alarm is generated. |
|
RoleName |
Specifies the role for which the alarm is generated. |
|
HostName |
Specifies the host for which the alarm is generated. |
|
Additional Information |
Detail |
Specifies the details for which the alarm is generated. |
Impact on the System
The OMS database cannot be managed and data cannot be accessed.
Possible Causes
The password of user ommdba is about to expire.
Handling Procedure
Check whether the password of user ommdba in the system is about to expire.
- Log in to the faulty node as user root.
Run the chage -l ommdba command to view the information about the password of user ommdba.
- View the value of Password expires to check whether the user configurations are about to expire.
If the parameter value is never, the user and password are valid permanently; if the value is a date, check whether the user and password are about to expire within 15 days.
- Run the chage -M 'days' ommdba command to set the validity period of the password for user ommdba. Eight hours later, check whether the alarm is automatically cleared.
- If it is, no further action is required.
- If it is not, go to 4.
Collect fault information.
- On FusionInsight Manager, choose O&M > Log > Download.
- Select NodeAgent for Service and click OK.
- Click in the upper right corner. In the displayed dialog box, set Start Date and End Date to 10 minutes before and after the alarm generation time respectively and click OK. Then, click Download.
- Contact the O&M engineers and send the collected log information.
Alarm Clearance
This alarm will be automatically cleared after the fault is rectified.
Related Information
None.