Updated on 2024-01-25 GMT+08:00

ALM-3276800045 Indicates that the board ports conflict with each other 147456

Description

ENTITYTRAP/4/PORTCONFLICT: OID [OID] Some ports on the board and subcard conflict with each other. (Index=[INTEGER], EntityPhysicalIndex=[INTEGER], PhysicalName="[OCTET]", EntityTrapEntType=[INTEGER], EntityTrapFaultID=[INTEGER], EntityTrapReasonDescr="[OCTET]")

The switch worked in card interface working mode, but no card was installed.

Attribute

Alarm ID

Alarm Severity

Alarm Type

3276800045

Warning

Equipment alarm

Parameters

Name

Meaning

OID

Indicates the MIB object ID of the alarm.

Index

Index.

EntityPhysicalIndex

Physical index.

PhysicalName

Entity name.

EntityTrapEntType

Entity type.

EntityTrapFaultID

Error code 147456.

EntityTrapReasonDescr

Cause of the alarm.

Impact on the System

The four 10GE SFP+ Ethernet optical interfaces on the front panel could not be used.

Possible Causes

The switch worked in card interface working mode, but no card was installed.

Procedure

Install a card supported by the switch.