ALM-135462925 hwBrdTempAlarm
Description
The board temperature exceeded the upper alarm threshold. (EntPhysicalIndex=[EntPhysicalIndex], EntPhysicalName=[EntPhysicalName], EntityThresholdType=[EntityThresholdType], EntityThresholdWarning=[EntityThresholdWarning], EntityThresholdCurrent=[EntityThresholdCurrent], EntityTrapFaultID=[EntityTrapFaultID], Reason=[ReasonDsp])
The board or card temperature was too high.
Attribute
Alarm ID |
OID |
Alarm Severity |
Alarm Type |
---|---|---|---|
135462925 |
1.3.6.1.4.1.2011.5.25.219.2.10.13 |
Minor |
Environmental alarm |
Parameters
Name | Meaning |
---|---|
EntPhysicalIndex |
Indicates the index of an entity. |
EntPhysicalName |
Indicates the name of an entity. |
EntityThresholdType |
Indicates the threshold type of the entity. |
EntityThresholdWarning |
Indicates the temperature threshold of the entity. |
EntityThresholdCurrent |
Indicates the current temperature. |
EntityTrapFaultID |
Indicates the error code. |
ReasonDsp |
Indicates a possible cause. |
Impact on the System
- Cause 1: Services are not affected temporarily, but the subcard temperature needs to be lowered as soon as possible.
- Cause 2: Services are not affected temporarily, but the board temperature needs to be lowered as soon as possible.
- Cause 3: Services are not affected temporarily, but the board temperature needs to be increased as soon as possible.
- Cause 4: Services are not affected temporarily, but the subcard temperature needs to be increased as soon as possible.
Possible Causes
- Cause 1: The card temperature was too high.
- Cause 2: The board temperature was too high.
- Cause 3: The board temperature fell below the lower limit.
- Cause 4: The subcard temperature fell below the lower limit.
Procedure
- Cause 1: The card temperature was too high.
- Check whether the air filter of the fan is blocked.
- If so, clean the air filter.
- If not, go to step 2.
- Check whether the ambient temperature is too high.
- If so, reduce the ambient temperature.
- If not, go to step 3.
- Check whether the fan is faulty.
- If so, rectify the fan fault.
- If not, go to step 4.
- Check whether a filler panel is installed in the slot that has no subcard installed.
- If so, go to step 5.
- If not, install a filler panel in the slot.
- Collect traps, logs, and configurations, and contact technical support personnel.
- Check whether the air filter of the fan is blocked.
- Cause 2: The board temperature was too high.
- Check whether the air filter of the fan is blocked.
- If so, clean the air filter.
- If not, go to step 2.
- Check whether the ambient temperature is too high.
- If so, reduce the ambient temperature.
- If not, go to step 3.
- Check whether the fan is faulty.
- If so, rectify the fan fault.
- If not, go to step 4.
- Check whether a filler panel is installed in the slot that has no board installed.
- If so, go to step 5.
- If not, install a filler panel in the slot.
- Collect traps, logs, and configurations, and contact technical support personnel.
- Check whether the air filter of the fan is blocked.
- Cause 3: The board temperature fell below the lower limit.
- Adjust the ambient temperature or increase the distance between the device and the air conditioner.
- Collect trap, log, and configuration information, and contact Huawei technical support personnel.
- Cause 4: The subcard temperature fell below the lower limit.
- Adjust the ambient temperature or increase the distance between the device and the air conditioner.Collect trap, log, and configuration information, and contact Huawei technical support personnel.