Help Center/ GeminiDB/ GeminiDB Influx API/ Best Practices/ Suggestions on Alarm Rules of GeminiDB Influx Instance Metrics
Updated on 2025-07-02 GMT+08:00

Suggestions on Alarm Rules of GeminiDB Influx Instance Metrics

After setting alarm rules on the Cloud Eye console, for example, specifying monitored objects and notification policies, you can stay ahead of your instance status. For details, see Configuring Alarm Rules.

This section describes recommended alarm rules of GeminiDB Influx instances.

Table 1 Suggestions on alarm rules of GeminiDB Influx instance metrics

Metric ID

Metric Name

Dimension

Threshold (Raw Value) in Best Practices

Alarm Severity in Best Practices

Alarm Handling Suggestion

gemini001_cpu_usage

CPU Usage

Node

> 90% for 3 consecutive periods

Major

Upgrade instance specifications. For details, see Changing vCPUs and Memory.

gemini002_mem_usage

Memory Usage

Node

> 80% for 3 consecutive periods

Major

Upgrade instance specifications. For details, see Changing vCPUs and Memory.

nosql005_disk_usage

Storage Space Usage

Instance

> 80% for 3 consecutive periods

Major

Evaluate how much storage needs to be added based on data growth. For details, see Manually Scaling Up Storage Space of a GeminiDB Influx Instance.

influxdb005_write_concurrency

Concurrent Write Requests

Node

≥ CPU cores x 4 for 3 consecutive periods

Major

Check whether the service traffic increases sharply and whether the database is normal. For details, see Viewing Metrics.

influxdb006_query_concurrency

Concurrent Queries

Node

≥ CPU cores for 3 consecutive periods

Major

Check whether the service traffic increases sharply and whether the database is normal. For details, see Viewing Metrics.