Metric ID |
Metric Name |
Dimension |
Threshold (Raw Value) in Best Practices |
Alarm Severity in Best Practices |
Alarm Handling Suggestion |
---|---|---|---|---|---|
gemini001_cpu_usage |
CPU Usage |
Node |
> 90% for 3 consecutive periods |
Major |
Upgrade instance specifications. For details, see Changing vCPUs and Memory. |
gemini002_mem_usage |
Memory Usage |
Node |
> 80% for 3 consecutive periods |
Major |
Upgrade instance specifications. For details, see Changing vCPUs and Memory. |
nosql005_disk_usage |
Storage Space Usage |
Instance |
> 80% for 3 consecutive periods |
Major |
Evaluate how much storage needs to be added based on data growth. For details, see Manually Scaling Up Storage Space of a GeminiDB Influx Instance. |
influxdb005_write_concurrency |
Concurrent Write Requests |
Node |
≥ CPU cores x 4 for 3 consecutive periods |
Major |
Check whether the service traffic increases sharply and whether the database is normal. For details, see Viewing Metrics. |
influxdb006_query_concurrency |
Concurrent Queries |
Node |
≥ CPU cores for 3 consecutive periods |
Major |
Check whether the service traffic increases sharply and whether the database is normal. For details, see Viewing Metrics. |