Querying Members in a Specified Device Group
Typical Scenario
An NA can call this API to query information about members in a specified device group.
API Function
This API is used by an NA to query the information about a device in a specified device group on the IoT platform.
API Description
1 |
public function queryDeviceGroupMembers($qdgmInDTO, $accessToken)
|
Parameter Description
Parameter |
Mandatory or Optional |
Location |
Description |
---|---|---|---|
$qdgmInDTO |
Mandatory |
query |
For details, see QueryDeviceGroupMembersInDTO structure. |
$accessToken |
Mandatory |
header |
This parameter is set to the value of the access token obtained by calling the Authentication API. |
Parameter |
Mandatory or Optional |
Location |
Description |
---|---|---|---|
$devGroupId |
Mandatory |
query |
Identifies a device group. The value of this parameter is returned by the IoT platform after the device group is added. |
$accessAppId |
Optional |
query |
If the device group belongs to the current application, set this parameter to null. Otherwise, set this parameter to the ID of the authorized application. |
$pageNo |
Optional |
query |
Indicates the page number. Default value: 0
|
$pageSize |
Optional |
query |
Indicates the number of devices on each page. The default value is 10. |
Response Parameters
QueryDeviceGroupMembersOutDTO
Parameter |
Description |
---|---|
$totalCount |
Indicates the number of devices in the device group. |
$pageNo |
Indicates the page number. |
$pageSize |
Indicates the number of devices on each page. |
$deviceIds |
Identifies the devices in the device group. |
Error Codes
HTTP Status Code |
Error Code |
Error Description |
Remarks |
---|---|---|---|
400 |
107001 |
The serviceId is not exist. |
The service ID does not exist. Recommended handling: Check whether serviceId carried in the API request is correct. |
400 |
107002 |
The properties is empty in database. |
The device attributes do not exist. Recommended handling: Check whether serviceId carried in the API request is correct. |
400 |
107003 |
The request properties is unknown. |
The device status is unknown. Recommended handling: Check whether the connection between the device and the IoT platform is normal. |
403 |
100203 |
The application is not existed. |
The application does not exist. Recommended handling:
|
403 |
100217 |
The application hasn't been authorized. |
The application has not been authorized. Recommended handling: In scenarios where applications are not authorized, ensure that request parameter appId is null. |
403 |
1010009 |
app throttle exceed. |
The NA calls the API at a frequency that exceeds the flow control threshold (100 calls per minute by default). Recommended handling: Contact IoT platform maintenance personnel to adjust the flow control threshold or control the API call frequency. |
403 |
1010005 |
App_key or access_token is invalid. |
The access token is invalid. Recommended handling: Check whether accessToken carried in the API request is correct. |
500 |
100203 |
The application is not existed. |
The application does not exist. Recommended handling:
|
500 |
50252 |
Internal server error. |
An internal server error occurs. Recommended handling: An internal error occurs on the IoT platform. Contact IoT platform maintenance personnel. |
Feedback
Was this page helpful?
Provide feedbackThank you very much for your feedback. We will continue working to improve the documentation.See the reply and handling status in My Cloud VOC.
For any further questions, feel free to contact us through the chatbot.
Chatbot