Deleting a Device Group
Typical Scenario
If a device group is no longer needed on the IoT platform due to group changes, an NA can call this API to delete a specified device group.
API Function
This API is used by an NA to delete a specified device group based on group ID from the IoT platform.
API Prototype
Method |
DELETE |
---|---|
URL |
https://server:port/iocm/app/devgroup/v1.3.0/devGroups/{devGroupId}?accessAppId={accessAppId} |
Transport Protocol |
HTTPS |
Request Parameters
Parameter |
Mandatory or Optional |
Type |
Location |
Description |
---|---|---|---|---|
app_key |
Mandatory |
String |
header |
Identifies an application that can be accessed on the IoT platform. The value of this parameter is allocated by the IoT platform when the application is created on the platform. |
Authorization |
Mandatory |
String |
header |
Indicates the authentication information for accessing the IoT platform. The value is Bearer {accessToken}, in which {accessToken} indicates the access token returned by the Authentication API. |
devGroupId |
Mandatory |
String |
path |
Identifies a device group. The value of this parameter is returned by the IoT platform after the device group is added. |
accessAppId |
Optional |
String |
query |
This parameter must be specified when you want to delete a device group under an authorized application. Set this parameter to the ID of the authorized application. |
Response Parameters
Status Code: 200 OK
Request Example
Method: DELETE Request: https://server:port/iocm/app/devgroup/v1.3.0/devGroups/{devGroupId}?accessAppId={accessAppId} Header: app_key: ****** Authorization: Bearer ****** Content-Type: application/json
Response Example
Response: Status Code: 200 OK
Error Codes
HTTP Status Code |
Error Code |
Error Description |
Remarks |
---|---|---|---|
200 |
100203 |
The application is not existed. |
The application does not exist. Recommended handling:
|
200 |
100217 |
The application hasn't been authorized |
The application has not been authorized. Recommended handling: In scenarios where applications are not authorized, ensure that request parameter appId is null. |
200 |
100603 |
The device group is not existed |
The device group does not exist. Recommended handling: Check whether the device group ID is correct. |
403 |
1010009 |
app throttle exceed. |
The NA calls the API at a frequency that exceeds the flow control threshold (100 calls per minute by default). Recommended handling: Contact IoT platform maintenance personnel to adjust the flow control threshold or control the API call frequency. |
403 |
1010005 |
App_key or access_token is invalid. |
The access token is invalid. Recommended handling: Check whether accessToken carried in the API request is correct. |
500 |
50252 |
Internal server error. |
An internal server error occurs. Recommended handling: An internal error occurs on the IoT platform. Contact IoT platform maintenance personnel. |