Updated on 2024-01-17 GMT+08:00

ALM-12035 Unknown Data Status After Recovery Task Failure (For MRS 2.x or Earlier)

Description

If a recovery task fails, the system attempts to automatically roll back. If the rollback fails, data may be lost. If this occurs, an alarm is reported. This alarm is cleared when the recovery task is successfully executed later.

Attribute

Alarm ID

Alarm Severity

Auto Clear

12035

Critical

Yes

Parameters

Parameter

Description

ServiceName

Specifies the service for which the alarm is generated.

RoleName

Specifies the role for which the alarm is generated.

HostName

Specifies the host for which the alarm is generated.

TaskName

Specifies the task name.

Impact on the System

The data may be lost or the data status may be unknown, which may affect services.

Possible Causes

The possible cause of this alarm is that the component status does not meet the requirements before the restoration task is executed or an error occurs in a step during the restoration task. The error depends on the task details. You can obtain logs and task details to handle the alarm.

Procedure

Checking the component status

  1. Log in to MRS Manager and choose Services. On the page that is displayed, check whether the running status of the components meets the requirements. (OMS and DBService must be in the normal status, and other components must be stopped.)

    • If yes, go to 7.
    • If no, go to 2.

  2. Restore the component status as required and start the recovery task again.
  3. Log in to MRS Manager and choose Alarms. In the alarm list, click the row containing the alarm and obtain the task name from the Location area.
  4. Choose System > Recovery Management. Search for the restoration task based on the task name and view the task details.
  5. Start the restoration task and check whether the task is executed.

    • If yes, go to 6.
    • If no, go to 7.

  6. After 2 minutes, check whether the alarm is cleared.

    • If yes, no further action is required.
    • If no, go to 7.

Collecting fault information

  1. On MRS Manager, choose System > Export Log.
  2. Contact the O&M engineers and send the collected logs.

Alarm Clearing

This alarm is automatically cleared after the fault is rectified.

Reference

None