Help Center> MapReduce Service> User Guide> Alarm Reference (Available for MRS 3.x)> ALM-50401 Number of JobServer Jobs Waiting to Be Executed Exceeds the Threshold
Updated on 2024-06-19 GMT+08:00

ALM-50401 Number of JobServer Jobs Waiting to Be Executed Exceeds the Threshold

Alarm Description

The system checks the number of jobs submitted to JobServer every 30 seconds. This alarm is generated when the number of jobs to be executed exceeds 800.

Alarm Attributes

Alarm ID

Alarm Severity

Auto Cleared

50401

Critical (default threshold: 900)

Major (default threshold: 800)

Yes

Alarm Parameters

Parameter

Description

Source

Specifies the cluster or system for which the alarm was generated.

ServiceName

Specifies the service for which the alarm was generated.

RoleName

Specifies the role for which the alarm was generated.

HostName

Specifies the host for which the alarm was generated.

Impact on the System

Too many JobServer jobs are detected in the queue. For details about the queue usage, see the Additional Information field of this alarm. The impacts are as follows:

  1. When the number of JobServer jobs in the queue reaches the maximum (1000 by default), new jobs cannot be added.
  2. Before the number of JobServer jobs in the queue reaches the maximum, new JobServer jobs cannot be submitted quickly. For example, it takes more time (even hours) to submit added jobs or add new jobs to Yarn.

Possible Causes

Too many jobs are submitted instantaneously.

Handling Procedure

  1. Log in to FusionInsight Manager and choose Cluster > Services > JobGateway.
  2. Click the Instances tab, click Add Instance, and add JobServer instances based on the number of submitted jobs.
  1. After the instances are added, restart the JobGateway service.

    The job functions of JobGateway will become unavailable during the service restart.

  2. Wait 5 minutes and check whether the alarm is automatically cleared.

    If yes, no further action is required.

    If no, go to 5.

Collect fault information.

  1. On FusionInsight Manager, choose O&M. In the navigation pane on the left, choose Log > Download.
  2. Expand the Service drop-down list, and select JobGateway for the target cluster.
  3. Click in the upper right corner, and set Start Date and End Date for log collection to 10 minutes ahead of and after the alarm generation time, respectively. Then, click Download.
  1. Contact O&M personnel and provide the collected logs.

Alarm Clearance

This alarm is automatically cleared after the fault is rectified.

Related Information

None.