ALM-45456 ClickHouse Distributed DDL Task Not Completed Within Expected Time
Alarm Description
The system checks each ClickHouse node for distributed DDL tasks that have been running longer than the default threshold (600 seconds) every 5 minutes. This alarm is triggered when such tasks are detected. The execution timeout for distributed DDL tasks can be queried and adjusted using the slow_ddl_cost_time parameter in the ClickHouse service configuration.
This alarm is automatically cleared when the system detects that the execution time of tasks in the distributed DDL queue does not exceed the threshold.
This section applies only to MRS 3.6.0-LTS or later.
Alarm Attributes
| Alarm ID | Alarm Severity | Auto Cleared |
|---|---|---|
| 45456 | Major | Yes |
Alarm Parameters
| Type | Parameter | Description |
|---|---|---|
| Location Information | Source | Specifies the cluster or system for which the alarm was generated. |
| ServiceName | Specifies the service for which the alarm was generated. | |
| RoleName | Specifies the role for which the alarm was generated. | |
| HostName | Specifies the host for which the alarm was generated. |
Impact on the System
If the ClickHouse service has a distributed DDL task that has not been completed for a long time, subsequent DDL tasks may be blocked, and metadata changes cannot be synchronized in the cluster in a timely manner.
Possible Causes
- ClickHouseServer instance failure
- Accumulated mutation tasks
Handling Procedure
Check whether ClickHouseServer instances are faulty.
- Log in to FusionInsight Manager, choose O&M > Alarm > Alarms, and view the role name and the IP address for the hostname in Location.
- Choose Cluster > Services > ClickHouse > Instances, and check whether the ClickHouse instance associated with the alarm IP address is faulty.
- Wait several minutes and check whether the alarm is cleared.
- If yes, no further action is required.
- If no, go to Step 4.
Check whether there are accumulated mutation tasks.
- Log in to the node where the client is installed as the client installation user and run the following commands:
cd {Client installation path}
source bigdata_env
- For a cluster with Kerberos authentication enabled (security mode):
clickhouse client --host IP address of the ClickHouseServer instance for which the alarm is reported --port 9440 --secure
- For a cluster with Kerberos authentication disabled (normal mode):
clickhouse client --host IP address of the ClickHouseServer instance for which the alarm is reported --userUsername --password --port 9440
- For a cluster with Kerberos authentication enabled (security mode):
- Run the following statement to check the task type in system.mutations and check whether there is a mutation task that has not been executed for a long time (more than 10 minutes):
select FQDN() as node, database, table, mutation_id, create_time, command, is_done, parts_to_do FROM clusterAllReplicas('default_cluster', system.mutations) WHERE is_done = 0; - Based on the query results in Step 5, confirm the table name related to the mutation task and try to clear the mutation task that has not been executed for a long time.
KILL MUTATION WHERE database = 'Database name' AND table = 'Table name';
Or
KILL MUTATION WHERE database = 'Database name' AND table = 'Table name' AND mutation_id = 'mutation_id';
alter table ... UPDATE and DELETE tasks are mutation tasks, which consume a large number of system resources and severely affect cluster performance. Do not frequently execute such tasks.
- After the mutation task is cleared, wait for a while and check whether the alarm is cleared.
- If yes, no further action is required.
- If no, go to Step 8.
Collect fault information.
- On FusionInsight Manager, choose O&M. In the navigation pane on the left, choose Log > Download.
- Expand the Service drop-down list and select ClickHouse for the target cluster.
- Expand the Hosts drop-down list. In the Select Host dialog box that is displayed, select the abnormal host and click OK.
- Click the edit icon in the upper right corner, and set Start Date and End Date for log collection to 1 hour ahead of and after the alarm generation time, respectively. Then, click Download.
- Contact O&M engineers and provide the collected logs.
Alarm Clearance
This alarm is automatically cleared after the fault is rectified.
Related Information
None