ALM-45436 Skew ClickHouse Table Data

Alarm Description

This alarm is generated when data skew occurs in the local table of a distributed table between ClickHouse nodes. This alarm is automatically cleared when data becomes balanced.

Data skew check method:

  • If min_table_check_data_bytes is set to 0, data skew check is disabled.
  • If min_table_check_data_bytes is greater than 0, data skew check is enabled.

After data skew check is enabled, if the data volume in a table is less than the min_table_check_data_bytes value, no alarm will be reported due to data skew. When the data volume is greater than the min_table_check_data_bytes value and the data volume difference between the same table on different nodes is greater than the percentage specified in min_table_data_varies_rate, data skew occurs and this alarm is reported.

Alarm Attributes

Alarm ID

Alarm Severity

Auto Cleared

45436

Minor

Yes

Alarm Parameters

Parameter

Description

Source

Specifies the cluster or system for which the alarm is generated.

ServiceName

Specifies the service for which the alarm is generated.

RoleName

Specifies the role for which the alarm is generated.

Table

Specifies the database name and table name for which the alarm is generated.

Impact on the System

SQL execution efficiency may be lowered.

Possible Causes

The data write policy is improper, causing unbalanced data among nodes.

Handling Procedure

  1. Log in to FusionInsight Manager, choose O&M > Alarm > Alarms, and view the role name and the IP address for the hostname in Location.
  2. Log in to the node where the client is installed as the client installation user and run the following commands:

    cd {Client installation path}

    source bigdata_env

    • Security mode (with Kerberos enabled):

      kinit Component service user

      clickhouse client --host IP address of the ClickHouseServer instance that reports the alarm --port 9440 --secure

    • Normal mode (with Kerberos disabled):

      clickhouse client --host IP address of the ClickHouseServer instance that reports the alarm --user Username --password --port 9000

  3. View data distribution.

    select FQDN(), database, table, sum(data_compressed_bytes) from clusterAllReplicas(Name of the logical cluster, system.parts) where database='Database name' and table='Table name' and active=1 group by (FQDN(), database, table);

  4. Balance data with a few clicks or migrate data based on service requirements.
  5. Check whether the alarm is cleared.

    • If yes, no further action is required.
    • If no, go to 6.

Collect fault information.

  1. On FusionInsight Manager, choose O&M. In the navigation pane on the left, choose Log > Download.
  2. Expand the Service drop-down list, and select ClickHouse for the target cluster.
  3. Expand the Hosts drop-down list. In the Select Host dialog box that is displayed, select the abnormal host, and click OK.
  4. Click the edit icon in the upper right corner, and set Start Date and End Date for log collection to 1 hour ahead of and after the alarm generation time, respectively. Then, click Download.
  5. Contact O&M personnel and provide the collected logs.

Alarm Clearance

This alarm is automatically cleared after the fault is rectified.

Related Information