Help Center> ModelArts> Troubleshooting> Training Jobs> GPU Issues> Error Message "RuntimeError: connect() timed out" Displayed in Logs
Updated on 2024-04-30 GMT+08:00

Error Message "RuntimeError: connect() timed out" Displayed in Logs

Symptom

When PyTorch is used for distributed training, the following error occurs.

Figure 1 Error log

Possible Causes

If data is copied before this issue occurs, data copy on all nodes is not complete at the same time. If you perform torch.distributed.init_process_group() when data copy is still in progress on certain nodes, the connection timed out.

Solution

If the issue is caused by asynchronous data copy between nodes and no barrier occurs, perform torch.distributed.init_process_group() before copying data, copy data based on local_rank()==0, call torch.distributed.barrier(), and wait until data copy is complete on all nodes. For details, see the following code:
import moxing as mox
import torch

torch.distributed.init_process_group()
if local_rank == 0: 
    mox.file.copy_parallel(src,dst) 

torch.distributed.barrier()

Summary and Suggestions

Before creating a training job, use the ModelArts development environment to debug the training code to maximally eliminate errors in code migration.