Help Center/ MapReduce Service/ User Guide (Ankara Region)/ Alarm Reference/ ALM-50215 Longest Duration of RPC Requests Received by Each FE Thrift Method Exceeds the Threshold
Updated on 2024-11-29 GMT+08:00

ALM-50215 Longest Duration of RPC Requests Received by Each FE Thrift Method Exceeds the Threshold

Alarm Description

The system checks the longest duration of RPC requests received by each FE Thrift method every 30 seconds. This alarm is generated when the longest duration exceeds the threshold (5000 ms by default).

This alarm is cleared when the longest duration of RPC requests received by each FE Thrift method is less than the threshold.

Alarm Attributes

Alarm ID

Alarm Severity

Alarm Type

Service Type

Auto Cleared

50215

Major

Quality of service

Doris

Yes

Alarm Parameters

Type

Parameter

Description

Location Information

Source

Specifies the cluster or system for which the alarm is generated.

ServiceName

Specifies the service for which the alarm is generated.

RoleName

Specifies the role for which the alarm is generated.

HostName

Specifies the host for which the alarm is generated.

Additional Information

Detail

Specifies the alarm triggering condition.

Impact on the System

A longer RPC duration indicates a higher performance load and slower network request processing, which may cause service congestion.

Possible Causes

  • The network has a latency.
  • There are too many concurrent large SQL tasks.

Handling Procedure

  1. Log in to the host where the faulty node is deployed as user root and run ping IP addresses of all Doris nodes to check whether the peer host can be pinged.

    • If yes, go to 3.
    • If no, go to 2.

  2. Contact the network administrator to restore the network.
  3. On FusionInsight Manager, choose Cluster > Services > Doris. Click the Chart tab, select Connection from Chart Category in the left pane, and view the FE MySQL Port Connections chart. If the number of connections is large, click Instances, select the FE instance, and click the Chart tab. Select CPU and Memory from Chart Category and view the CPU Usage of FE chart. If the CPU usage is high, check the Time field in FE audit log /var/log/Bigdata/audit/doris/fe/fe.audit.log to collect statistics on the average task duration. If the value is also high, the alarm is caused by large concurrent tasks.
  4. Log in to FusionInsight Manager, choose O&M > Alarm > Thresholds, click the name of the desired cluster, and choose Doris > Performance > Longest duration of RPC requests received by each method of the FE thrift interface (FE).
  5. Click the edit button next to Trigger Count, change the number based on site requirements, and click OK.
  6. Click Modify in the Operation column, change the alarm threshold based on site requirements, and click OK.
  7. Wait 10 minutes and check whether the alarm is automatically cleared.

    • If yes, no further action is required.
    • If no, go to 8.

Collect fault information.

  1. On FusionInsight Manager, choose O&M. In the navigation pane on the left, choose Log > Download.
  2. Expand the Service drop-down list, and select Doris for the target cluster.
  3. Click the edit icon in the upper right corner, and set Start Date and End Date for log collection to 1 hour ahead of and after the alarm generation time, respectively. Then, click Download.
  4. Contact O&M engineers and provide the collected logs.

Alarm Clearance

This alarm is automatically cleared after the fault is rectified.

Related Information

None.