ALM-46008 MOTService Memory Usage Exceeds the Threshold
Alarm Description
The system checks the memory usage every 30 seconds and compares the actual memory usage with the threshold. This alarm is generated when the memory usage exceeds the threshold.
- If Trigger Count is 1, this alarm is cleared when the MOTService memory usage is less than or equal to the threshold.
- If Trigger Count is greater than 1, this alarm is cleared when the MOTService memory usage is less than or equal to 70% of the threshold.
Alarm Attributes
Alarm ID |
Alarm Severity |
Alarm Type |
Service Type |
Auto Cleared |
---|---|---|---|---|
46008 |
Critical (default threshold: 80%) Major (default threshold: 75%) |
Physical resource |
MOTService |
Yes |
Alarm Parameters
Type |
Parameter |
Description |
---|---|---|
Location Information |
Source |
Specifies the cluster or system for which the alarm was generated. |
ServiceName |
Specifies the service for which the alarm was generated. |
|
RoleName |
Specifies the role for which the alarm was generated. |
|
HostName |
Specifies the host for which the alarm was generated. |
|
Additional Information |
Trigger Condition |
Specifies the threshold for triggering the alarm. |
Impact on the System
Service processes respond slowly or become unavailable. As a result, the MOTService database cannot provide functions such as data import and query for upper-layer services.
Possible Causes
- The alarm threshold or alarm trigger count is improperly configured.
- The memory size cannot meet service requirements, and the memory usage reaches the upper limit.
Handling Procedure
Check whether the alarm threshold or alarm trigger count is properly configured.
- Log in to FusionInsight Manager, choose O&M > Alarm > Thresholds, click the name of the desired cluster, choose MOTService > Database > MOT Used Memory Percentage (MOTServer), and check whether the alarm trigger count and alarm threshold are set properly.
- Change the trigger count and alarm threshold based on the actual memory usage, and apply the changes.
- Wait 2 minutes and check whether the alarm is automatically cleared.
- If yes, no further action is required.
- If no, go to 4.
Check the memory usage.
- On FusionInsight Manager, choose O&M > Alarm > Alarms. In the right pane, click this alarm and obtain the host name in Location.
- Choose Hosts and click the host for which the alarm is generated.
- Observe the real-time data of the MOTService memory usage for about 5 minutes. If the memory usage exceeds the threshold for multiple times, contact the MRS cluster administrator to increase the memory.
- Check whether the alarm is cleared.
- If yes, no further action is required.
- If no, go to 8.
Collect fault information.
- On FusionInsight Manager, choose O&M. In the navigation pane on the left, choose Log > Download.
- Expand the Service drop-down list and select MOTService.
- Expand the Hosts drop-down list. In the Select Host dialog box that is displayed, select the hosts to which the role belongs.
- Click the edit icon in the upper right corner, and set Start Date and End Date for log collection to 10 minutes ahead of and after the alarm generation time, respectively. Then, click Download.
- Contact O&M personnel/Technical support and provide the collected logs.