ALM-45282 UserSync Direct Memory Usage Exceeds the Threshold
Alarm Description
The system checks the direct memory usage of the UserSync service every 60 seconds. This alarm is generated when the direct memory usage of the UserSync instance exceeds the threshold (80% of the maximum memory) for five consecutive times. This alarm is cleared when the UserSync direct memory usage is less than or equal to the threshold.
Alarm Attributes
Alarm ID |
Alarm Severity |
Alarm Type |
Service Type |
Auto Cleared |
---|---|---|---|---|
45282 |
Major |
Quality of service |
Ranger |
Yes |
Alarm Parameters
Type |
Parameter |
Description |
---|---|---|
Location Information |
Source |
Specifies the cluster for which the alarm is generated. |
ServiceName |
Specifies the service for which the alarm is generated. |
|
RoleName |
Specifies the role for which the alarm is generated. |
|
HostName |
Specifies the host for which the alarm is generated. |
|
Additional Information |
Trigger Condition |
Specifies the alarm triggering condition. |
Impact on the System
The service may break down. Ranger cannot synchronize LDAP user information.
Possible Causes
The direct memory of the UserSync instance is overused or the direct memory is inappropriately allocated. As a result, the memory usage exceeds the threshold.
Handling Procedure
Check the direct memory usage.
- On FusionInsight Manager, choose O&M > Alarm > Alarms > ALM-45282 UserSync Direct Memory Usage Exceeds the Threshold. Check the location information of the alarm. Check the name of the instance host for which the alarm is generated.
- On FusionInsight Manager, choose Cluster > Services > Ranger > Instance. Select the role corresponding to the host name of the instance for which the alarm is generated. Click the drop-down list in the upper right corner of the chart area and choose Customize > CPU and Memory > UserSync Direct Memory Usage. Click OK.
- Check whether the direct memory used by the UserSync reaches the threshold (80% of the maximum direct memory by default).
- On FusionInsight Manager, choose Cluster > Services > Ranger > Instance > UserSync > Instance Configuration. Click All Configurations, and choose UserSync > System. Increase the value of -XX:MaxDirectMemorySize in the GC_OPTS parameter based on the site requirements and save the configuration.
If this alarm is generated, the direct memory configured for UserSync cannot meet the direct memory required by the UserSync process. You are advised to check the direct memory usage of UserSync and change the value of -XX:MaxDirectMemorySize in GC_OPTS to the twice of the direct memory used by UserSync. You can change the value based on the actual service scenario. For details, see 2.
- Restart the affected services or instances and check whether the alarm is cleared.
- If yes, no further action is required.
- If no, go to 6.
Collect the fault information.
- On FusionInsight Manager, choose O&M. In the navigation pane on the left, choose Log > Download.
- Expand the Service drop-down list, and select Ranger for the target cluster.
- Click in the upper right corner, and set Start Date and End Date for log collection to 10 minutes ahead of and after the alarm generation time, respectively. Then, click Download.
- Contact O&M engineers and provide the collected logs.
Alarm Clearance
This alarm is automatically cleared after the fault is rectified.