Help Center/ MapReduce Service/ User Guide (Ankara Region)/ Alarm Reference/ ALM-12018 Memory Usage Exceeds the Threshold
Updated on 2024-11-29 GMT+08:00

ALM-12018 Memory Usage Exceeds the Threshold

Alarm Description

The system checks the memory usage of the system every 30 seconds and compares the actual memory usage with the threshold. The memory usage has a default threshold, this alarm is generated when the value of the memory usage exceeds the threshold.

When the Trigger Count is 1, this alarm is cleared when the host memory usage is less than or equal to the threshold. When the Trigger Count is greater than 1, this alarm is cleared when the host memory usage is less than or equal to 90% of the threshold.

Alarm Attributes

Alarm ID

Alarm Severity

Alarm Type

Service Type

Auto Cleared

12018

Critical (default threshold: 95%)

Major (default threshold: 90%)

Physical resource

FusionInsight Manager

Yes

Alarm Parameters

Type

Parameter

Description

Location Information

Source

Specifies the cluster or system for which the alarm is generated.

ServiceName

Specifies the service for which the alarm is generated.

RoleName

Specifies the role for which the alarm is generated.

HostName

Specifies the host for which the alarm is generated.

Additional Information

Trigger Condition

Specifies the triggering condition for which the alarm is generated.

Impact on the System

  • Latency: If the host memory usage is too high, service processes may run slowly and services may be delayed.
  • Service failure: If the host memory usage is too high, memory overflow may occur in service processes and jobs may fail.

Possible Causes

Memory configuration cannot meet service requirements. The memory usage reaches the upper limit.

Handling Procedure

Expand the system.

  1. In the alarm list on FusionInsight Manager, click in the row where the alarm is located to view the alarm host address in the alarm details.
  2. Log in to the host where the alarm is generated as user root.
  3. If the memory usage exceeds the threshold, perform memory capacity expansion.
  4. Run the command free -m | grep Mem\: | awk '{printf("%s,", $3 * 100 / $2)}' to check the system memory usage.
  5. Wait for 5 minutes, check whether the alarm is cleared.

    • If yes, no further action is required.
    • If no, go to 6.

Collect fault information.

  1. On the FusionInsight Manager in the active cluster, choose O&M > Log > Download.
  2. Select OmmServer from the Service and click OK.
  3. Click the edit button in the upper right corner, and set Start Date and End Date for log collection to 10 minutes ahead of and after the alarm generation time, respectively. Then, click Download.
  4. Contact the O&M engineers and send the collected log information.

Alarm Clearance

After the fault is rectified, the system automatically clears this alarm.

Related Information

None.