ALM-135463100 hwIfMonitorCrcErrorRising
Description
The CRC error is rising. (hwIfMonitorIndex=[EntityPhysicalIndex], hwIfMonitorCrcErrorStatistics=[hwIfMonitorCrcErrorStatistics], hwIfMonitorCrcErrorThreshold=[hwIfMonitorCrcErrorThreshold], hwIfMonitorCrcErrorInterval=[hwIfMonitorCrcErrorInterval], EntPhysicalName=[EntPhysicalName], hwIfMonitorAllStatistics=[hwIfMonitorAllStatistics])
The number of CRC error packets received by the interface in a specified period exceeded the upper threshold.
Attribute
AlarmID |
Alarm OID |
Alarm Severity |
Alarm Type |
---|---|---|---|
135463100 |
1.3.6.1.4.1.2011.5.25.41.4.1 |
Critical |
Processing error alarm |
Parameters
Name |
Meaning |
---|---|
OID |
Indicates the MIB object ID of the alarm. |
EntityPhysicalIndex |
Entity index. |
hwIfMonitorCrcErrorStatistics |
Real-time statistics of CRC error packets |
hwIfMonitorCrcErrorThreshold |
Upper threshold for the number of CRC error packets |
hwIfMonitorCrcErrorInterval |
Configured statistics collection interval |
EntPhysicalName |
Entity name |
hwIfMonitorAllStatistics |
Number of packets in real-time statistics |
Impact on the System
An interface receives a large number of CRC error packets, which may cause the interface to transit to the Error-Down state.
Possible Causes
The interface receives excessive CRC error packets whose lengths are greater than or equal to 64 bytes in a specified period of time.
Procedure
1. Run the display this command in the interface view to check whether the alarm threshold for error packets is too low.Determine the alarm threshold based on service requirements.
- If so, go to Step 2.
- If no, go to Step 3.
2. Run the trap-threshold crc-statistics command in the interface view to set a larger alarm threshold for error packets. Then check whether the alarm is cleared.
- If yes, no further action is required.
- If no, go to Step 3.
3. Collect trap, log, and configuration information, and contact technical support personnel.