Help Center/ Huawei Qiankun CloudService/ More Documents/ Device Alarm Handling/ V500 Firewall Alarms/ ALM-303046698 The card or subcard temperature is too high 143617
Updated on 2024-01-25 GMT+08:00

ALM-303046698 The card or subcard temperature is too high 143617

Description

SRM_ENTITY/6/ENTITYBRDTEMPALARM:OID 1.3.6.1.4.1.2011.5.25.219.2.10.13 Temperature rise over or fall below the warning alarm threshold. (Index=[integer], EntityPhysicalIndex=[integer], PhysicalName="[STRING]", EntityThresholdType=[integer], EntityThresholdValue=[integer], EntityThresholdCurrent=[integer], EntityTrapFaultID=143617)

The board or subcard temperature was too high.

Attribute

Alarm ID

Alarm Severity

Alarm Type

303046698

Major

equipmentAlarm

Parameters

Name

Meaning

OID

Indicates the MIB object ID of the alarm.

Index

Indicates the index.

EntityPhysicalIndex

Indicates the physical entity index.

EntPhysicalName

Indicates the physical entity name.

EntityType

Indicates the entity type.

EntityTrapFaultID

Indicates the error code.

Impact on the System

The device may be restarted, causing service interruption.

Possible Causes

Cause 1: The board temperature exceeds the upper alert threshold.

Cause 2: The fan is faulty.

Procedure

  1. Run the display device command and check whether the fan status restores normal.

    • Y =>2
    • N =>3

  2. Lower the ambient temperature, run the display temperature all command, and check whether the board temperature is Normal.

    • Y =>4
    • N =>3

  3. Collect the information about alarms, logs, and configurations, and then contact Huawei technical support personnel.
  4. End.

Related Information

None