Description

WLAN/2/AP_IOT_SERVER_START_FAIL:OID [OID] Failed to start the server used by the IoT card. (Cause: The UDP port is occupied.) (APMAC=[OPAQUE], APName=[STRING], ApIotCardId=[INTEGER], UdpPort=[INTEGER], APID=[INTEGER])

The server module on an AP for receiving data from the IoT card fails to start.

Attribute

Alarm ID

Alarm Severity

Alarm Type

3276800198

Major

Communication alarm

Parameters

Name

Meaning

OID

ID of a MIB object.

APMAC

MAC address of an AP.

APName

Name of an AP.

ApIotCardId

Number of the slot on an AP where an IoT card is installed.

UdpPort

UDP port number.

APID

ID of an AP.

Impact on the System

The server module on an AP for receiving data from the IoT card fails to start, and services are not available.

Possible Causes

The port used by the server module on the AP for receiving data from the IoT card is occupied.

Procedure

Change the IP address and port number.