Updated on 2024-01-25 GMT+08:00

ALM-3276800185 A port is powered off

Description

WLAN/4/AP_POE_POWER_OFF:OID [oid] A port is powered off. (APMAC=[OPAQUE], APName=[STRING], ApIfIndex=[INTEGER], ApEntityPhysicalName=[OCTET], APID=[INTEGER], Reason=[STRING])

The PD connected to the interface is powered off.

Only the AP4050DN-E, AP4050DN-HD, AP7050DN-E, AP7052DN, AP7152DN, AD9430DN-24, AD9431DN-24X and AD9430DN-12 support this alarm.

Attribute

Alarm ID

Alarm Severity

Alarm Type

3276800185

Warning

Equipment alarm

Parameters

Name

Meaning

OID

Indicates the MIB object ID of the alarm.

APMAC

Indicates the AP's MAC address.

APName

Indicates the AP name.

ApIfIndex

Indicates the AP interface index.

ApEntityPhysicalName

Indicates the AP interface name.

APID

Indicates the AP ID.

Reason

Indicates the power-off reason.

Impact on the System

The PD connected to the interface is powered off and cannot work normally.

Possible Causes

Cause 1: The PD is removed.

Cause 2: The PD is faulty.

Cause 3: When the power is insufficient, the interface with higher priority preempts the power.

Cause 4: The interface is automatically powered off in the power-off time range.

Procedure

  1. Check whether the PD is removed.

    • If so, go to step 2.
    • If not, go to step 3.

  2. Install the PD and check whether the alarm is cleared.

    • If so, go to step 11.
    • If not, go to step 3.

  3. Check whether the power is sufficient.

    • If so, go to step 7.
    • If not, go to step 4.

  4. Check whether the priority of the interface is low.

    • If so, go to step 5.
    • If not, go to step 8.

  5. Check whether the interface priority is proper according to the requirements for the interface priority.

    • If yes, use the poe priority (AP wired port link profile view) command to re-set the interface priority.
    • If not, increase the PoE power.

  6. Check whether the alarm is cleared.

    • If so, go to step 11.
    • If not, go to step 7.

  7. Check whether the PD is faulty.

    • If so, go to step 8.
    • If not, go to step 9.

  8. Replace the PD and check whether the alarm is cleared.

    • If so, go to step 11.
    • If not, go to step 9.

  9. Check whether the interface is in the power-off time range.

    • If so, go to step 11.
    • If not, go to step 10.

  10. Contact technical support personnel.
  11. End