ALM-3276800134 Indicates that the stack physical port state has changed to down
Description
FSP/3/STACKPORTISDOWN: OID [OID] Stack port [octet] state is down.
A member port that has been added to a logical stack port becomes Down.
Attribute
Alarm ID |
Alarm Severity |
Alarm Type |
---|---|---|
3276800134 |
Minor |
Communication alarm |
Parameters
Name |
Meaning |
---|---|
OID |
Indicates the MIB object ID of the alarm. |
[octet] |
Indicates the local interface name. |
Impact on the System
None
Possible Causes
The member port is not connected.
Procedure
- If no, connect it using a cable. The alarm handling ends.
- If so, rectify the fault according to An Ethernet Interface Is Physically Down in the product documentation of the corresponding device.