ALM-3276800132 Logical Ports of a Stack Were Connected Incorrectly.
Description
FSP/3/LOGPORT_ILLEGAL: OID [OID] Stack port [octet1] connects to [octet2], and there are port members of the same logic stack port ID.
The logical stack ports are connected in a wrong order. The switch requires that the member ports in logical stack port 1 be connected to the member ports in stack port 2.
Attribute
Alarm ID |
Alarm Severity |
Alarm Type |
---|---|---|
3276800132 |
Minor |
Communication alarm |
Parameters
Name |
Meaning |
---|---|
OID |
Indicates the MIB object ID of the alarm. |
[octet1] |
Indicates the local interface name. |
[octet2] |
Indicates the name of remote interface connected to the local interface. |
Impact on the System
The stack cannot be set up or the link generating the alarm is unavailable.
Possible Causes
The logical stack ports are connected in a wrong order.
Procedure
- Run the display stack port command to check member ports of logical stack ports.
- Connect the member ports in the local logical stack port 1 to those in the remote logical stack port 2, and connect the member ports in the local logical stack port 2 to those in the remote logical stack port 1.
Related Information
None