Help Center/ Huawei Qiankun CloudService/ More Documents/ Device Alarm Handling/ V200 LSW Alarms/ ALM-3276800130 Indicates that the stack-port state has changed to up
Updated on 2024-01-25 GMT+08:00

ALM-3276800130 Indicates that the stack-port state has changed to up

Description

FSP/4/STACKPORT_UP: OID [OID] Stack-port [integer]/[integer] changes to up.

This alarm was sent to the NMS by the master switch when the logical stack port of a switch in the stack system was Up.

Attribute

Alarm ID

Alarm Severity

Alarm Type

3276800130

Warning

Equipment alarm

Parameters

Name

Meaning

OID

Indicates the MIB object ID of the alarm.

[integer]

Stack ID of the device generating the alarm.

[integer]

ID of the logical stack port whose status changes on the device. This ID starts from 0.

Impact on the System

If the stack interface is Up, service interfaces in the stack system increase. Services, however, are not interrupted.

If the stack interface is Down, the stack system recalculates the ring-breaking point, and then refreshes the forwarding entries. In this case, services are transiently interrupted and automatically recover after the forwarding entries are refreshed.

Possible Causes

1. The switch in the stack system was powered on.

2. The running switch was added to the stack system.

Procedure

This alarm is informational only, and no action is required.

Related Information

None