Help Center/ Huawei Qiankun CloudService/ More Documents/ Device Alarm Handling/ V200 LSW Alarms/ ALM-3276800016 MPP joins AC through the air notify
Updated on 2024-01-25 GMT+08:00

ALM-3276800016 MPP joins AC through the air notify

Description

WLAN/4/MPP_JOINED_ON_AIR:OID [oid] MPP can't reach AC through the Ethernet port,so this MPP joins AC through the air,changes itself to MP,and forbid traffic on the Ethernet port in avoid of loopback. (APMAC=[OPAQUE], APName=[STRING], APID=[INTEGER])

An MPP changes to an MP and goes online through an air interface.

Attribute

Alarm ID

Alarm Severity

Alarm Type

3276800016

Warning

Communication alarm

Parameters

Name

Meaning

OID

Indicates the MIB object ID of the alarm.

APMAC

Indicates the MAC address of an AP.

APName

Indicates the AP name.

APID

Indicates the AP ID.

Impact on the System

None

Possible Causes

Due to a link fault, an MPP changes to an MP and goes online through an air interface.

Procedure

This alarm is informational only, and no action is required.

Related Information