Help Center/ Huawei Qiankun CloudService/ More Documents/ Device Alarm Handling/ V200 LSW Alarms/ ALM-3276800012 Indicates that PHY abnormal 67958
Updated on 2024-01-25 GMT+08:00

ALM-3276800012 Indicates that PHY abnormal 67958

Description

SRM/3/ENTITYINVALID: OID [OID] PHY is abnormal. (EntityPhysicalIndex=[INTEGER], BaseTrapSeverity=[INTEGER], BaseTrapProbableCause=[INTEGER], BaseTrapEventType=[INTEGER], EntPhysicalContainedIn=[INTEGER], EntPhysicalName=[OCTET], RelativeResource=[OCTET], ReasonDescription=[OCTET])

The PHY is faulty.

Attribute

Alarm ID

Alarm Severity

Alarm Type

3276800012

Minor

Equipment alarm

Parameters

Name

Meaning

OID

Indicates the MIB object ID of the alarm.

EntityPhysicalIndex

Indicates a physical entity index.

BaseTrapSeverity

Indicates the alarm severity.

BaseTrapProbableCause

Indicates the error code of the alarm.

BaseTrapEventType

Indicates the event type.

EntPhysicalContainedIn

Indicates contained physical entity code.

EntPhysicalName

Indicates the physical entity name.

RelativeResource

Indicates a sub-entity.

ReasonDescription

Describes reason of the fault.

Impact on the System

The interface specified in the alarm cannot send or receive packets. The RUN indicator of the device is off, and the Alarm indicator is steady red.

Possible Causes

The PHY hardware component became faulty.

Procedure

Use a normally running interface to replace the faulty interface, and reconfigure service parameters on this interface.