Updated on 2024-01-25 GMT+08:00

ALM-303046965 Loop exist in vlan

Description

L2IFPPI/4/MFLPVLANALARM:OID [OID] Loop exist in vlan [INTEGER], for [OCTET].

MAC address flapping occurs.

Attribute

Alarm ID

Alarm Severity

Alarm Type

303046965

Warning

Communication alarm

Parameters

Name

Meaning

OID

Indicates the MIB object ID of the alarm.

VLAN

Indicates the VLAN ID.

OCTET

Indicates the cause why the interface is blocked.

Impact on the System

Traffic cannot be received normally.

Possible Causes

Cause 1: The interfaces where loops occur are added to the same VLAN.

Cause 2: Cables are connected incorrectly.

Cause 3: Loop detection and STP are enabled to remove loops on the network.

Procedure

  1. Check that cables are connected correctly. Then check whether the alarm is still reported.

    • If yes, go to step 2.
    • If not, go to step 6.

  2. Check whether the two interfaces that learn the same MAC address can be added to different VLANs according to the networking.

    • If yes, go to step 3.
    • If not, go to step 4.

  3. Modify the configuration and add the two interfaces that learn the same MAC address to different VLANs. Then check whether the alarm is still reported.

    • If yes, go to step 4.
    • If not, go to step 6.

  4. Disable loop detection and enable STP. Then check whether the alarm is still reported.

    • If yes, go to step 5.
    • If not, go to step 6.

  5. Contact technical support personnel.
  6. End.

Related Information

None