Updated on 2024-01-25 GMT+08:00

ALM-303046937 Attack occurred

Description

SECE/4/STRACKPORT: OID=[OID] Attack occurred.(Interface=[STRING], CVLAN=[ULONG], PVLAN=[ULONG], EndTime=[STRING], TotalPackets=[ULONG])

The system detects an attack on an interface.

Attribute

Alarm ID

Alarm Severity

Alarm Type

303046937

Warning

securityServiceOrMechanismViolation

Parameters

Name

Meaning

OID

Indicates the MIB object ID of the alarm.

Interface

Indicates the access interface of the attacker.

CVLAN

Indicates the outer VLAN ID of the attacker.

PVLAN

Indicates the inner VLAN ID of packets sent from the attacker.

EndTime

Indicates the end time of the attack.

TotalPackets

Indicates the number of packets received from the attacker.

Impact on the System

The CPU is busy processing attack packets. As a result, normal service packets cannot be processed in time or even discarded.

Possible Causes

The number of packets with the specified interface and VLAN ID sent to the CPU exceeds the alarm threshold.

Procedure

  1. If an attack is initiated by a user and the user is the only one connected to the interface, you can shut down the interface and check whether the interface is normal.
  2. If the interface is connected to multiple users and some users initiate attacks, you can set the action taken on attack packets to deny, or configure a traffic policy to discard attack packets.
  3. If only entries exist on the interface or entries cannot be determined, collect device configurations, alarms, and logs, and then contact technical support personnel.
  4. End.

Related Information