ALM-303046733 The Number of Global DHCP Users Reached the Lower Alarm Threshold
Description
DHCP/4/DHCPUSERBINDTRAPGLOBALRESUME:OID [OID] The number of DHCP global users descends to alarm threshold. (IfIndex=[INTEGER], VlanIndex=[INTEGER], CurrentUser=[INTEGER], MaxUser=[INTEGER])
The number of global DHCP users reached the lower alarm threshold.
Attribute
Alarm ID |
Alarm Severity |
Alarm Type |
---|---|---|
303046733 |
Warning |
equipmentAlarm |
Parameters
Name |
Meaning |
---|---|
OID |
Indicates the MIB object ID of the alarm. |
IfIndex |
Indicates the interface index. The value is 0. |
VlanIndex |
Indicates the VLAN index. The value is 0. |
CurrentUser |
Indicates the number of current access users. |
MaxUser |
Indicates the maximum number of access users. |
Impact on the System
None
Possible Causes
The number of global DHCP snooping binding entries reached the lower alarm threshold.
Procedure
- Run the dhcp snooping max-user-number max-user-number command to adjust the maximum number of access users allowed on the interface.
- Run the dhcp snooping user-alarm percentage percent-lower-value percent-upper-value command to adjust the alarm thresholds.
Related Information
None