Help Center/ Huawei Qiankun CloudService/ More Documents/ Device Alarm Handling/ WAC&AP Alarms/ ALM-303046720 The Percentage of Successfully Authenticated NAC Users Reached the Upper Alarm Threshold
Updated on 2024-01-25 GMT+08:00

ALM-303046720 The Percentage of Successfully Authenticated NAC Users Reached the Upper Alarm Threshold

Description

AAA/4/NACMaxUserAlarm: OID [OID] The number of NAC users reached the maximum.(Slot:[OCTET] User-num:[INTEGER] Threshold:[INTEGER]%)

The percentage of successfully authenticated NAC users reached the upper alarm threshold.

Attribute

Alarm ID

Alarm Severity

Alarm Type

303046720

Warning

equipmentAlarm

Parameters

Name

Meaning

[OID]

Indicates the MIB object ID of the alarm.

Slot:[OCTET]

Indicates the slot ID.

User-num:[INTEGER]

Indicates the number of successfully authenticated NAC users.

Threshold:[INTEGER]%

Indicates the percentage of successfully authenticated NAC users.

Impact on the System

None

Possible Causes

The percentage of successfully authenticated NAC users reached the upper alarm threshold.

Procedure

  1. Run the display authentication user-alarm configuration command in any view to check the upper alarm threshold for the percentage of successfully authenticated NAC users. Adjust the threshold according to the network requirements. If the fault persists, go to step 2.
  2. Collect log information and contact technical support engineers.