ALM-303046409 The Power Supply Experienced a Partial Failure
Description
ENTITYTRAP/3/TRAPID_ENTITY_POWER_FAIL:OID [OID] Power become failure.(EntityPhysicalIndex=[INTEGER], PhysicalName=\"[OCTET]\",EntityTrapFaultID=[INTEGER], EntityOperStatus=[INTEGER],EntityTrapReasonDescr=\"[OCTET]\")
The power supply may fail.

This alarm is supported only by the AC6805.
Attribute
Alarm ID |
Alarm Severity |
Alarm Type |
---|---|---|
303046409 |
Major |
equipmentAlarm |
Parameters
Name |
Meaning |
---|---|
OID |
Indicates the MIB object of the alarm. |
EntityPhysicalIndex |
Indicates the index of the physical entity. |
PhysicalName |
Indicates the physical entity name. |
EntityTrapFaultID |
Indicates the error code. |
EntityOperStatus |
Indicates the faulty status. |
EntityTrapReasonDescr |
Indicates the description of the alarm cause. |
Impact on the System
The device may fail to run properly.
Possible Causes
Error Code |
Possible Cause |
---|---|
136961 |
Voltage information failed to be obtained from the I2C interface. |
136962 |
Overvoltage occurred. |
136963 |
Undervoltage occurred. |
Procedure
- Replace the power supply and check whether the alarm persists.
- If so, go to step 2.
- If not, no further action is required.
- Collect alarms, logs, and configurations, and then contact technical support engineers.
Related Information
None