ALM-4289601651 The number of forward sessions has reached the threshold value
Description
FWDTRAP/2/SESSIONRESLACKREPORT: OID [oid] The forward session resources were overloaded.(SessionType = "[OCTET]", ThresholdLevel = [INTEGER], CurrentNum = [INTEGER], TotalNum = [INTEGER], Usage = [INTEGER]%, Top3SourceIpAddress=[OCTET])

- If the number of forwarding flow tables changes too rapidly within a short period of time, multiple alarms may be generated. As a result, the system records these alarms, affecting normal services on the device. To prevent the device from recording a large number of alarms, the system suppresses the alarms by setting the interval at which alarms are sent to longer than 30 minutes. That is, the system records an alarm at least 30 minutes after the last alarm was cleared.
- This alarm is supported in V300R022C00SPC100 and later versions.
Attribute
Alarm ID |
OID |
Alarm Severity |
Alarm Type |
---|---|---|---|
4289601651 |
1.3.6.1.4.1.2011.5.25.227.2.1.38 |
Major |
Quality Of Service Alarm |
Parameters
Name |
Meaning |
---|---|
[oid] |
Indicates the MIB object ID of the alarm. |
SessionType |
Alarm type. Currently, only SESSION is supported. |
ThresholdLevel |
Alarm severity:
|
CurrentNum |
Number of forwarding flow tables. |
TotalNum |
Maximum number of forwarding flow tables. |
Usage |
Proportion that the number of forwarding flow tables on the device accounts for of the maximum number. |
Top3SourceIpAddress |
Three source IP addresses with the largest number of forwarding flow tables and their corresponding numbers of forwarding flow tables. Format: (Source IP address 1, Number of forwarding flow tables 1) (Source IP address 2, Number of forwarding flow tables 2) (Source IP address 3, Number of forwarding flow tables 3) |
Impact on the System
Services are affected.
Possible Causes
Cause 1: The number of forwarding flow tables on the device reached or exceeded the level-1 alarm threshold (90%).
Cause 2: The number of forwarding flow tables on the device reached or exceeded the level-2 alarm threshold (100%).
Procedure
Check service configurations and contact technical support personnel.
Clearing
After the fault is rectified, the system clears this alarm, removing the need to manually clear it. This alarm will not be displayed on the CurrentAlarms page.