ALM-4288421944 VM Memory Usage Exceeding the Threshold
Description
EVM/2/EVM_MEM_USAGE_RISING:OID [OID] VM Memory utilization exceeded the pre-alarm threshold.(VMName=\"[octet]\", ThresholdWarning=[INTEGER], Thresholdcurrent=[INTEGER])
The VM memory usage exceeded the threshold.
Attribute
Alarm ID |
OID |
Alarm Severity |
Alarm Type |
---|---|---|---|
4288421944 |
1.3.6.1.4.1.2011.5.25.348.2.6.1 |
Major |
Equipment alarm |
Parameters
Name |
Meaning |
---|---|
OID |
Indicates the MIB object ID of the alarm. |
VMName |
Indicates a VM name. |
ThresholdWarning |
Indicates the alarm threshold. |
Thresholdcurrent |
Indicates the memory usage. |
Impact on the System
Services are affected.
Possible Causes
The configured VM specifications do not meet current service requirements.
Procedure
- Based on the VM type, log in to the VM and check whether the total memory and CPU usage of all supported services are normal.
- If so, go to step 2.
- If not, rectify the fault. If the fault is still there, go to step 3.
- Configure a VM with a higher memory or reduce services. Check whether the alarm is cleared.
- If the alarm is cleared, go to step 4.
- If the alarm persists, go to step 3.
- Collect alarm information, log information, and configuration, and contact technical support personnel.
- End.
Clearing
After the fault is rectified, the system clears this alarm, removing the need to manually clear it. This alarm will not be displayed on the Current Alarms page.