ALM-3276800303 Power is unusable
Description
ENTITYTRAP/1/POWERUNUSEABLE:OID [OID] Power change to unusable status.(Index=[INTEGER1], EntityPhysicalIndex=[INTEGER2], PhysicalName="[OCTET]", EntityTrapFaultID=[INTEGER3])
The power supply is unavailable.

Only the switch models with dual power supplies support this alarm.
Attribute
Alarm ID |
OID |
Alarm Severity |
Alarm Type |
---|---|---|---|
3276800303 |
1.3.6.1.4.1.2011.5.25.219.2.5.7 |
Critical |
Equipment alarm |
Parameters
Name |
Meaning |
---|---|
OID |
Indicates the MIB object ID of the alarm. |
Index |
Indicates an entity index. |
EntityPhysicalIndex |
Indicates a physical index. |
PhysicalName |
Indicates a physical entity name. |
EntityTrapFaultID |
Indicates the fault ID. |
Impact on the System
Services are interrupted.
Possible Causes
- Cause 1: The device's power cable was removed.
- Cause 2: A power module was faulty.
Procedure
- Check whether the power cable is removed.
- If the power cable is working properly, check whether the power module is working properly.
- If the power module is working properly, upgrade the system software or patch software to the latest version.
- Collect alarm and configuration information, and contact technical support personnel.
Related Information
None
Feedback
Was this page helpful?
Provide feedbackThank you very much for your feedback. We will continue working to improve the documentation.See the reply and handling status in My Cloud VOC.
For any further questions, feel free to contact us through the chatbot.
Chatbot