Predefined Big Screen

The predefined big-screen monitoring function allows users to display monitoring services such as topologies on high-resolution screens, facilitating the display of monitoring information and IT O&M effects of multiple smart modules.

Prerequisites

  • You have the operation rights of View, Predefined Screen and Predefined Screen Setting.
  • You have the operation rights of View, Single Line, Chiller Group Control, Energy Analysis, and View Access Control Events.
  • You have the management domain permissions for equipment rooms, outlets, and containers.

Procedure

  1. Choose Device Management > Big Screen Monitor > Predefined Big Screen.
  2. Select the equipment room for which you want to set the predefined big screen.

    1. Click in the upper part of the navigation tree.
    2. In the displayed dialog box, select the equipment room for which you want to set the predefined big screen.

      Only one predefined big screen can be created for an equipment room.

    3. Click Yes.

  3. Set the company name and logo, and predefine the greetings and display time format on the big screen.

    1. Click in the upper left corner to set the company name and logo.
    2. Click above the topology to set the predefined big screen greeting.
    3. Click in the upper right corner to set the time format.

  4. Set the service type and equipment room view display mode.

    1. Click in the upper right corner of a service in the monitoring view to set the service data type.
      • You must have the operation rights of Energy Analysis to view PUE, Power Consumption Comparison, and Power Consumption Trend.
      • You must have the operation rights of View Access Control Events to view Access Event.
      • You must have the operation rights of View to view Alarm Information.
    2. Click in the upper right corner of the topology to select the view display mode, and determine whether to show or hide the single-line electrical diagram and chiller group control. When Choose View Mode is set to 3D, you can perform operations in Table 1.

      You must have the operation rights of View, Single Line, and, Chiller Group Control to view the 2D, 2.5D, and 3D topology views, single-line electrical diagrams, and chiller group control diagrams.

      Table 1 view operation tasks

      Operation

      Description

      Procedure

      Adjusting views

      Adjust the view effect to stay in the optimal view.

      Zoom and rotate the view.

      View details about the smart module in the equipment room.

      The 3D view supports the drill-down function to view details about smart modules in the equipment room.

      Double-click the smart module or device to be viewed to drill down, and right-click to return to the previous layer.

      Viewing the space, power distribution, and cooling capacity of a cabinet

      Display the space, power distribution, and cooling capacity of each cabinet in 3D mode.

      Select Power, Cooling or Space on the right of the view.

      Setting wall display status

      Make equipment room walls transparent to highlight information about other devices in the equipment room.

      Select Transparent on the right of the view.

      Setting the Device Display Status

      The sensors and cameras connected to the equipment room are displayed in the 3D topology.

      Select Device Location on the right of the view, and then click the button for displaying the device.

    3. View KPIs of key devices in the lower part of the topology.

  5. Click Save.
  6. In the displayed dialog box, enter the name of the predefined big screen and click OK.

Follow-up Procedure

In the navigation tree on the left, choose a predefined big screen and perform the following operations:

If You Need to...

Then...

Modify the unit screen name.

Click . When the status becomes editable, you can modify the unit screen name.

Delete a unit screen.

Click to delete a predefined big screen.