Updated on 2025-10-30 GMT+08:00

Querying Alarm Policies

Function

This API is used to query alarm policies by alarm rule ID.

Debugging

You can debug this API through automatic authentication in API Explorer or use the SDK sample code generated by API Explorer.

Authorization Information

Each account has all the permissions required to call all APIs, but IAM users must be assigned the required permissions.

  • If you are using role/policy-based authorization, see Permissions Policies and Supported Actions for details on the required permissions.
  • If you are using identity policy-based authorization, the following identity policy-based permissions are required.

    Action

    Access Level

    Resource Type (*: required)

    Condition Key

    Alias

    Dependencies

    ces:alarms:getPolicies

    Read

    alarm *

    • g:ResourceTag/<tag-key>

    • g:EnterpriseProjectId

    • ces:alarms:get

    -

URI

GET /v2/{project_id}/alarms/{alarm_id}/policies

Table 1 Path Parameters

Parameter

Mandatory

Type

Description

project_id

Yes

String

Definition

Project ID. It is used to specify the project that an asset belongs to. You can query the assets of a project by project ID. You can obtain the project ID from the API or console. For details, see Obtaining a Project ID.

Constraints

N/A

Range

1 to 64 characters

Default Value

N/A

alarm_id

Yes

String

Definition

Alarm rule ID.

Constraints

N/A

Range

The value starts with al and is followed by 22 characters that may include letters, digits, or a combination of both. The value can contain a total of 24 characters.

Default Value

N/A

Table 2 Query Parameters

Parameter

Mandatory

Type

Description

offset

No

Integer

Definition

Pagination offset.

Constraints

N/A

Range

0-10000

Default Value

0

limit

No

Integer

Definition

Number of records displayed on each page.

Constraints

N/A

Range

1-100

Default Value

10

Request Parameters

Table 3 Request header parameters

Parameter

Mandatory

Type

Description

Content-Type

No

String

Definition

MIME type of the request body.

Constraints:

None

Value range:

The value can contain 1 to 64 characters.

Default value:

The default type is application/json; charset=UTF-8.

X-Auth-Token

No

String

Definition

User token.

Constraints:

None

Value range:

The value can contain 1 to 16,384 characters.

Default value:

None

Response Parameters

Status code: 200

Table 4 Response body parameters

Parameter

Type

Description

policies

Array of ListPolicyResp objects

Definition

List of alarm policies.

count

Integer

Definition

Total number of policies in an alarm rule.

Range

0-100

Table 5 ListPolicyResp

Parameter

Type

Description

metric_name

String

Definition

Metric name of a resource. For details about the metrics of each service, see Service Metric Names.

Range

The value must start with a letter and can only contain digits, letters, underscores (_), and hyphens (-). 1 to 96 characters For example, the ECS metric cpu_util indicates the CPU usage of an ECS. The DDS metric mongo001_command_ps indicates the command execution frequency.

extra_info

MetricExtraInfoResp object

Definition

Additional information about the alarm policy.

period

Integer

Definition

Interval (seconds) for checking whether the alarm rule conditions are met.

Range

The value can be:

  • 0: default value. This value can be used for event alarms.

  • 1: original metric period. For example, if the original period of an RDS metric is 60s, the metric data is collected and calculated every 60s.

  • 300: The metric data is collected and calculated every 5 minutes.

  • 1200: The metric data is collected and calculated every 20 minutes.

  • 3600: The metric data is collected and calculated every hour.

  • 14400: The metric data is collected and calculated every 4 hours.

  • 86400: The metric data is collected and calculated every day.

filter

String

Definition

Aggregation method.

Range

average, variance, min, max, or sum

comparison_operator

String

Definition

Threshold symbol.

Range

The value can be >, <, >=, <=, =, !=, cycle_decrease, cycle_increase, or cycle_wave. cycle_decrease indicates the decrease relative to the last period; cycle_increase indicates the increase relative to the last period; cycle_wave indicates the increase or decrease relative to the last period.

value

Number

Definition

Alarm threshold. For specific thresholds, see the value range of each metric in the appendix.

Range

The value ranges from 0 to 1.7976931348623157e+108.

hierarchical_value

HierarchicalValueResp object

Definition

Multi-level alarm threshold.

Range

When you create or modify an alarm rule, you can set only one threshold in the following scenarios:

  1. The alarm type is Metric and the alarm policy is Trigger an alarm when all policies are met.

  2. The alarm type is Event.

unit

String

Definition

Data unit.

Range

[0,32]

type

String

Definition

Alarm policy type. This API has been deprecated.

Constraints

N/A

Range

[0,32]

Default Value

N/A

count

Integer

Definition

Number of times that the alarm triggering conditions are met.

Range

For event alarms, the value ranges from 1 to 180. For metric and website alarms, the value can be 1, 2, 3, 4, 5, 10, 15, 30, 60, 90, 120, or 180.

suppress_duration

Integer

Definition

Alarm suppression duration, in seconds. This parameter corresponds to the last field in the alarm policy when you create an alarm rule. This field is used to mitigate frequent alarm occurrences.

Range

The value can be:

  • 0: An event alarm is not suppressed in the immediate triggering scenario, and is generated only once in the accumulated triggering scenario.generated only once.

  • 300: An alarm is generated every 5 minutes once the alarm triggering condition is met.

  • 600: An alarm is generated every 10 minutes once the alarm triggering condition is met.

  • 900: An alarm is generated every 15 minutes once the alarm triggering condition is met.

  • 1800: An alarm is generated every 30 minutes once the alarm triggering condition is met.

  • 3600: An alarm is generated every 60 minutes once the alarm triggering condition is met.

  • 10800: An alarm is generated every 3 hours once the alarm triggering condition is met.

  • 21600: An alarm is generated every 6 hours once the alarm triggering condition is met.

  • 43200: An alarm is generated every 12 hours once the alarm triggering condition is met.

  • 86000: An alarm is generated once every day once the alarm triggering condition is met.

level

Integer

Definition

Alarm severity.

Range

The value can be: 1 (critical), ** 2** (major), 3 (minor), or 4 (warning)

namespace

String

Definition

Service namespace. For details about the namespace of each service, see Service Namespaces.

Range

The value is in the service.item format. The values of service and item must be a string, starting with a letter and containing only digits (0–9), letters (case-insensitive), and underscores (_). The value contains 0 to 32 characters.

dimension_name

String

Definition

Metric dimension name. For details, see Service Dimension Names.

Range

The value must start with a letter. Each dimension allows a maximum of 32 characters and can only contain digits, letters, underscores (_), and hyphens (-). Multiple dimensions are separated by commas (,). A maximum of four dimensions are supported. Example: instance_id for single-dimension scenarios; instance_id,disk for multi-dimension scenarios.

Table 6 MetricExtraInfoResp

Parameter

Type

Description

origin_metric_name

String

Definition

Original metric name.

Range

[0,4,096]

metric_prefix

String

Definition

Metric name prefix.

Range

[0,4,096]

custom_proc_name

String

Definition

Name of a process.

Range

[0,250]

metric_type

String

Definition

Metric type.

Range

[0,32]

Table 7 HierarchicalValueResp

Parameter

Type

Description

critical

Double

Definition

Threshold for critical alarms.

Range

[-1.7976931348623157e+108, 1.7976931348623157e+108]

major

Double

Definition

Threshold for major alarms.

Range

[-1.7976931348623157e+108, 1.7976931348623157e+108]

minor

Double

Definition

Threshold for minor alarms.

Range

[-1.7976931348623157e+108, 1.7976931348623157e+108]

info

Double

Definition

Threshold for warnings.

Range

[-1.7976931348623157e+108, 1.7976931348623157e+108]

Status code: 400

Table 8 Response body parameters

Parameter

Type

Description

error_code

String

Status codes customized by each cloud service when a request error occurs.

error_msg

String

Request error message.

request_id

String

Request ID.

Status code: 404

Table 9 Response body parameters

Parameter

Type

Description

error_code

String

Status codes customized by each cloud service when a request error occurs.

error_msg

String

Request error message.

request_id

String

Request ID.

Status code: 500

Table 10 Response body parameters

Parameter

Type

Description

error_code

String

Status codes customized by each cloud service when a request error occurs.

error_msg

String

Request error message.

request_id

String

Request ID.

Example Requests

Query an alarm policy whose alarm_id is alCzk8o9dtSQHtiDgb44Eepw and limit is 10.

/v2/{project_id}/alarms/alCzk8o9dtSQHtiDgb44Eepw/policies?offset=0&limit=10

Example Responses

Status code: 200

Query succeeded.

{
  "policies" : [ {
    "namespace" : "AGT.ECS",
    "metric_name" : "disk_device_read_bytes_rate",
    "extra_info" : { },
    "period" : 1,
    "filter" : "average",
    "comparison_operator" : ">",
    "value" : 75,
    "hierarchical_value" : {
      "critical" : 1
    },
    "unit" : "byte/s",
    "count" : 3,
    "type" : "",
    "suppress_duration" : 10800,
    "level" : 2
  } ],
  "count" : 10
}

Status Codes

Status Code

Description

200

Query succeeded.

400

Parameter verification failed.

404

Alarm rule not found.

500

Internal system error.

Error Codes