Registering a Device (Verification Code Mode)
Typical Scenario
Before a device accesses the IoT platform by using verification code, an NA needs to call this API to register the device with the IoT platform and set a unique identification code of the device (such as the IMEI) as the verification code. Then, the device can use the unique identification code to get authenticated and connect to the IoT platform.
API Function
This API is used by an NA to register a device with the IoT platform. After registration, the device can connect to the IoT platform.
API Description
1 |
public function regDirectDevice($rddInDto, $appId, $accessToken)
|
Class
DeviceManagement
Parameter Description
Parameter |
Mandatory or Optional |
Location |
Description |
---|---|---|---|
$rddInDto |
Mandatory |
body |
For details, see RegDirectDeviceInDTO structure. |
$appId |
Mandatory |
query |
If the device belongs to the current application, set this parameter to null. Otherwise, set this parameter to the ID of the authorized application. |
$accessToken |
Mandatory |
header |
This parameter is set to the value of the access token obtained by calling the Authentication API. |
Parameter |
Mandatory or Optional |
Location |
Description |
---|---|---|---|
deviceInfo |
Optional |
Body |
Indicates the device information. For details, see DeviceInfo structure. |
endUserId |
Optional |
Body |
This parameter identifies an end user. In the NB-IoT solution, this parameter is set to the IMSI of the device. In the Smart Home solution, this parameter is set to the application account. |
imsi |
Optional |
Body |
Indicates the IMSI of an NB-IoT device. |
isSecure |
Optional |
Body |
Indicates whether the device is secure. The default value is false.
NOTE:
If a user needs to register a secure device, this parameter must be specified. |
nodeId |
Mandatory |
Body |
Uniquely identifies a device. The value of this parameter must be the same as the device ID reported by the device. Generally, the MAC address, serial number, or IMEI is used as the node ID.
NOTE:
When the IMEI is used as the node ID, the node ID varies depending on the chip provided by the manufacturer.
|
psk |
Optional |
Body |
If the pre-shared key (PSK) is specified in the request, the IoT platform uses the specified PSK. If the PSK is not specified in the request, the PSK is generated by the IoT platform. The value is a string of characters, including upper-case letters A to F, lower-case letters a to f, and digits 0 to 9. |
timeout |
Optional |
Body |
Indicates the validity period for device registration. When this API is called to register a device, the device can be bound within the validity period. If the device is not bound within the validity period, the registration information will be deleted. The value ranges from 0 to 2147483647. If this parameter is set to 0, the device verification code is always valid. (The recommended value is 0.) The default value is 180. The default value can be configured. For details, contact the IoT platform maintenance personnel. Unit: second |
verifyCode |
Conditionally optional Mandatory |
body |
Indicates the device verification code. If this parameter is specified in the request, it is returned in the response. If this parameter is not specified in the request, it is generated by the IoT platform. In the NB-IoT solution, this parameter is mandatory and must be set to the same value as nodeId. |
productId |
Optional |
Body |
Identifies the product to which the device belongs. |
Parameter |
Mandatory or Optional |
Location |
Description |
---|---|---|---|
manufacturerId |
Optional |
Body |
Uniquely identifies a manufacturer. |
manufacturerName |
Optional |
Body |
Indicates the manufacturer name. |
deviceType |
Optional |
Body |
Indicates the device type. The upper camel case is used, for example, MultiSensor, ContactSensor, and CameraGateway. |
model |
Mandatory |
Body |
Indicates the device model. In Z-Wave, the format is productType + productId. The value is a hexadecimal value in the format of XXXX-XXXX. Zeros are added if required, for example, 001A-0A12. The format in other protocols is still to be determined. |
protocolType |
Optional |
Body |
Indicates the protocol type used by the device. The value options are CoAP, huaweiM2M, Z-Wave, ONVIF, WPS, Hue, WiFi, J808, Gateway, ZigBee, and LWM2M. |
Return Value
RegDirectDeviceOutDTO
Parameter |
Description |
---|---|
$deviceId |
Identifies a device. |
$verifyCode |
Indicates a verification code that can be used by the device to obtain the device ID and password. If this parameter is specified in the request, it is returned in the response. If this parameter is not specified in the request, it is automatically generated by the IoT platform. |
$timeout |
Indicates the validity period of the verification code, in seconds. The device must connect to the IoT platform within this period. |
$psk |
Indicates a random PSK. If the PSK is carried in the request, it is used. Otherwise, the IoT platform generates a random PSK. |
Error Codes
HTTP Status Code |
Error Code |
Error Description |
Remarks |
---|---|---|---|
200 |
103028 |
The license pool resources. |
The license resources have been used up. |
400 |
100003 |
Invalid verify code. |
The verification code is invalid. Recommended handling: Check whether verifyCode carried in the API request is correct. If verifyCode is not carried in the API request, contact IoT platform maintenance personnel. |
400 |
100007 |
Bad request message. |
The request message contains invalid parameters. Recommended handling: The value of deviceId is not assigned. Set this parameter based on the description of request parameters. |
400 |
100416 |
The device has already been bounded. |
The device has been bound to the IoT platform. Recommended handling: Check whether the device is registered. |
400 |
100426 |
The nodeId is duplicated. |
The value of nodeId is duplicated. Recommended handling: Check whether nodeId carried in the API request is correct. |
400 |
50400 |
The input is invalid. |
An input parameter is invalid. Recommended handling: Check whether parameters carried in the API call request are valid. |
401 |
100025 |
AppId for auth not exist. |
The application ID used for authentication does not exist. Recommended handling:
|
403 |
100203 |
The application is not existed. |
The application does not exist. Recommended handling:
|
403 |
100217 |
The application has not been authorized. |
The application has not been authorized. Recommended handling: In scenarios where applications are not authorized, ensure that request parameter appId is null. |
403 |
1010009 |
app throttle exceed. |
The NA calls the API at a frequency that exceeds the flow control threshold (100 calls per minute by default). Recommended handling: Contact IoT platform maintenance personnel to adjust the flow control threshold or control the API call frequency. |
403 |
1010005 |
App_key or access_token is invalid. |
The access token is invalid. Recommended handling: Check whether accessToken carried in the API request is correct. |
403 |
600002 |
The product not existed. |
The product does not exist. Recommended handling: Check whether productId is correct. |
500 |
100001 |
Internal server error. |
An internal server error occurs. Recommended handling: An internal error occurs on the IoT platform. Contact IoT platform maintenance personnel. |
500 |
100203 |
The application is not existed. |
The authorized application does not exist. Recommended handling:
|
500 |
100412 |
The amount of device has reached the limit. |
The number of devices under the current application reaches the upper limit. Recommended handling: Check whether the number of devices under the current application reaches the upper limit. |
500 |
100441 |
The amount of nonSecure device has reached the limit. |
The number of non-security devices has reached the upper limit. |
500 |
103026 |
The license is not exist. |
The license does not exist. Recommended handling: An internal license error occurs on the IoT platform. Contact IoT platform maintenance personnel. |
500 |
50252 |
Internal server error. |
An internal server error occurs. Recommended handling: An internal error occurs on the IoT platform. Contact IoT platform maintenance personnel. |
Feedback
Was this page helpful?
Provide feedbackThank you very much for your feedback. We will continue working to improve the documentation.See the reply and handling status in My Cloud VOC.
For any further questions, feel free to contact us through the chatbot.
Chatbot