ALM-12045 Read Packet Dropped Rate Exceeds the Threshold (For MRS 2.x or Earlier)
Description
The system checks the read packet dropped rate every 30 seconds. This alarm is generated when the read packet dropped rate exceeds the threshold (the default threshold is 0.5%) for multiple times (the default value is 5).
You can change the threshold by choosing System > Threshold Configuration > Device > Host > Network Reading > Network Read Packet Rate Information > Read Packet Dropped Rate.
This alarm is cleared when hit number is 1 and the read packet dropped rate is less than or equal to the threshold. This alarm is cleared when hit number is greater than 1 and the read packet dropped rate is less than or equal to 90% of the threshold.
The alarm detection is disabled by default. If you want to enable this function, check whether this function can be enabled based on Checking System Environments.
Attribute
Alarm ID |
Alarm Severity |
Auto Clear |
---|---|---|
12045 |
Major |
Yes |
Parameters
Parameter |
Description |
---|---|
ServiceName |
Specifies the service for which the alarm is generated. |
RoleName |
Specifies the role for which the alarm is generated. |
HostName |
Specifies the host for which the alarm is generated. |
NetworkCardName |
Specifies the network port for which the alarm is generated. |
Trigger Condition |
Specifies the threshold for triggering the alarm. |
Impact on the System
The service performance deteriorates or some services time out.
Risk warning: In SUSE kernel 3.0 or later or Red Hat 7.2, the system kernel modifies the mechanism for counting the number of dropped read packets. In this case, this alarm may be generated even if the network is running properly, but services are not affected. You are advised to check the system environment first.
Possible Causes
- An OS exception occurs.
- The NICs are bonded in active/standby mode.
- The alarm threshold is improperly configured.
- The network environment is abnormal.
Procedure
View the network packet dropped rate.
- Use PuTTY to log in to any non-alarm node in the cluster as user omm and run the ping IP address of the node for which the alarm is generated -c 100 command to check whether packet drop occurs on the network.
# ping 10.10.10.12 -c 5 PING 10.10.10.12 (10.10.10.12) 56(84) bytes of data. 64 bytes from 10.10.10.11: icmp_seq=1 ttl=64 time=0.033 ms 64 bytes from 10.10.10.11: icmp_seq=2 ttl=64 time=0.034 ms 64 bytes from 10.10.10.11: icmp_seq=3 ttl=64 time=0.021 ms 64 bytes from 10.10.10.11: icmp_seq=4 ttl=64 time=0.033 ms 64 bytes from 10.10.10.11: icmp_seq=5 ttl=64 time=0.030 ms --- 10.10.10.12 ping statistics --- 5 packets transmitted, 5 received, 0% packet loss, time 4001ms rtt min/avg/max/mdev = 0.021/0.030/0.034/0.006 ms
- IP address of the node for which the alarm is generated: Query the IP address of the node for which the alarm is generated on the node management page of the MRS cluster details page based on the value of HostName in the alarm location information. Check both the IP addresses of the management plane and service plane.
- -c: number of check times. The default value is 100.
Check the system environment.
- Use PuTTY to log in to the active OMS node or the node for which the alarm is generated as user omm.
- Run the cat /etc/*-release command to check the OS type.
- Run the cat /etc/euleros-release command to check whether the OS version is EulerOS 2.2.
# cat/etc/euleros-release EulerOS release 2.0 (SP2)
- Run the cat /proc/version command to check whether the SUSE kernel version is 3.0 or later.
# cat /proc/version Linux version 3.0.101-63-default (geeko@buildhost) (gcc version 4.3.4 [gcc-4_3-branch revision 152973] (SUSE Linux) ) #1 SMP Tue Jun 23 16:02:31 UTC 2015 (4b89d0c)
- Log in to MRS Manager and choose System > Configuration > Threshold Configuration.
- In the navigation pane of the Threshold Configuration page, choose Network Reading > Network Read Packet Rate Information > Read Packet Dropped Rate. In the right pane, check whether Send Alarm is selected.
- In the right pane, deselect Send Alarm to shield alarm "Network Read Packet Dropped Rate Exceeds the Threshold."
- Go to the MRS cluster details page and choose Alarms.
- Search for alarm 12045 and manually clear the alarms that are not automatically cleared. No further action is required.
Figure 1 Alarm Management
The ID of alarm Network Read Packet Dropped Rate Exceeds the Threshold is 12045.
Check whether the NICs are bonded in active/standby mode.
- Use PuTTY to log in to the node for which the alarm is generated as user omm and run the ls -l /proc/net/bonding command to check whether the /proc/net/bonding directory exists on the node.
- If yes, as shown in the following figure, the bond mode is configured for the node. Go to 12.
# ls -l /proc/net/bonding/ total 0 -r--r--r-- 1 root root 0 Oct 11 17:35 bond0
- If no, the bond mode is not configured for the node. Go to 14.
# ls -l /proc/net/bonding/ ls: cannot access /proc/net/bonding/: No such file or directory
- If yes, as shown in the following figure, the bond mode is configured for the node. Go to 12.
- Run the cat /proc/net/bonding/bond0 command to check whether the value of Bonding Mode in the configuration file is fault-tolerance.
In the preceding command, bond0 is the name of the bond configuration file. Use the file name obtained in 11.
# cat /proc/net/bonding/bond0 Ethernet Channel Bonding Driver: v3.7.1 (April 27, 2011) Bonding Mode: fault-tolerance (active-backup) Primary Slave: eth1 (primary_reselect always) Currently Active Slave: eth1 MII Status: up MII Polling Interval (ms): 100 Up Delay (ms): 0 Down Delay (ms): 0 Slave Interface: eth0 MII Status: up Speed: 1000 Mbps Duplex: full Link Failure Count: 1 Slave queue ID: 0 Slave Interface: eth1 MII Status: up Speed: 1000 Mbps Duplex: full Link Failure Count: 1 Slave queue ID: 0
- Check whether the NIC specified by NetworkCardName in the alarm details is the standby NIC.
- If yes, the alarm of the standby NIC cannot be automatically cleared. Manually clear the alarm on the alarm management page. No further action is required.
- If no, go to 14.
To determine the standby NIC, check the /proc/net/bonding/bond0 configuration file. If the NIC name corresponding to NetworkCardName is Slave Interface but not Currently Active Slave (the current active NIC), the NIC is the standby one.
Check whether the threshold is set properly.
- Log in to MRS Manager and check whether the threshold (configurable, 0.5% by default) is appropriate.
- Choose System > Threshold Configuration > Device > Host > Network Reading > Network Read Packet Rate Information > Read Packet Dropped Rate and change the alarm threshold based on the actual service usage.
- Wait 5 minutes and check whether the alarm is cleared.
- If yes, no further action is required.
- If no, go to 17.
Check whether the network is normal.
- Contact the system administrator to check whether the network is normal.
- Wait 5 minutes and check whether the alarm is cleared.
- If yes, no further action is required.
- If no, go to 19.
- Collect fault information.
- On MRS Manager, choose .
- Contact the O&M engineers and send the collected logs.
Reference
None
Feedback
Was this page helpful?
Provide feedbackThank you very much for your feedback. We will continue working to improve the documentation.See the reply and handling status in My Cloud VOC.
For any further questions, feel free to contact us through the chatbot.
Chatbot