ALM-50403 Slow Job Submission on JobServer
This section applies only to MRS 3.5.1 and later versions.
Alarm Description
The system checks the latency of the job submission API in JobServer every 30 seconds. By default, a major alarm is reported when the latency exceeds 10s for three consecutive times and a critical alarm is reported when the latency exceeds 20s for three consecutive times. The alarm is cleared when the latency is lower than the threshold for three consecutive times.
Alarm Attributes
| Alarm ID | Alarm Severity | Auto Cleared |
|---|---|---|
| 50403 | Critical (default threshold: 20s) Major (default threshold: 10s) | Yes |
Alarm Parameters
| Type | Parameter | Description |
|---|---|---|
| Location Information | Source | Specifies the cluster or system for which the alarm was generated. |
| ServiceName | Specifies the service for which the alarm was generated. | |
| RoleName | Specifies the role for which the alarm was generated. | |
| HostName | Specifies the host for which the alarm was generated. | |
| Additional Information | Trigger Condition | Specifies the alarm triggering condition. |
Impact on the System
It takes a long time to submit a job, for example, through the REST API.
Possible Causes
The number of concurrent requests to JobServer on a node surges, or underlying services like DBService take a long time to respond.
Handling Procedure
- Log in to FusionInsight Manager, choose O&M > Alarm > Alarms, search for the alarm "ALM-50403 Slow Job Submission on JobServer", locate the abnormal JobServer instance node according to alarm information, and obtain CurrentValue in Additional Information.
For details about how to log in to FusionInsight Manager, see Accessing MRS Manager.
- On the alarm page, check whether there is a JobServer or DBService fault alarm.
- Rectify the fault by referring to the alarm help. Then, check whether the alarm is cleared.
- If yes, no further action is required.
- If no, go to Step 4.
Collect fault information.
- On FusionInsight Manager, choose O&M. In the navigation pane on the left, choose Log > Download.
- Expand the Service drop-down list, and select JobGateway for the target cluster.
- Click the edit icon in the upper right corner, and set Start Date and End Date for log collection to 10 minutes ahead of and after the alarm generation time, respectively. Then, click Download.
- Contact O&M engineers and provide the collected logs.
Alarm Clearance
This alarm is automatically cleared after the fault is rectified.
Related Information
None
What is your overall rating for this page?
Thank you very much for your feedback. We will continue working to improve the documentation.See the reply and handling status in My Cloud VOC.
For any further questions, feel free to contact us through the chatbot.