ALM-29107 Tserver Process Memory Usage Exceeds the Threshold
Alarm Description
The system checks the Kudu service status every 60 seconds. This alarm is generated when the memory usage of the Kudu Tserver process exceeds the threshold.
This alarm is cleared when the memory usage of the Tserver process becomes normal and the system considers that the Kudu instance service recovers.
Alarm Attributes
Alarm ID |
Alarm Severity |
Auto Cleared |
---|---|---|
29107 |
Critical |
Yes |
Alarm Parameters
Type |
Parameter |
Description |
---|---|---|
Location Information |
Source |
Specifies the cluster for which the alarm was generated. |
ServiceName |
Specifies the service for which the alarm was generated. |
|
RoleName |
Specifies the role for which the alarm was generated. |
|
HostName |
Specifies the host for which the alarm was generated. |
|
Additional Information |
Trigger Condition |
Specifies the threshold for triggering the alarm. |
Impact on the System
Users cannot use the Kudu service.
Possible Causes
The memory usage of the KuduTserver instance is too high.
Handling Procedure
Handle the Kudu instance exceptions.
- On FusionInsight Manager, choose O&M > Alarm > Alarms. On the displayed page, locate alarm ALM-29107 Tserver Process Memory Usage Exceeds the Threshold and view the alarm source.
- Choose O&M > Alarm > Thresholds > Kudu. Locate the alarm threshold, compare the memory usage of the KuduTserver instance in the cluster with the threshold, and find the node whose memory usage exceeds the threshold.
Add nodes or reschedule jobs to reduce the memory usage of the Tserver node or change the threshold.
- Choose O&M > Alarm and check whether the alarm is cleared.
- If yes, no further action is required.
- If no, go to 4.
Collect fault information.
- On FusionInsight Manager, choose O&M. In the navigation pane on the left, choose Log > Download.
- Expand the Service drop-down list, and select Kudu for the target cluster.
- Click in the upper right corner, and set Start Date and End Date for log collection to 10 minutes ahead of and after the alarm generation time, respectively. Then, click Download.
- Contact O&M personnel and provide the collected logs.
Alarm Clearance
This alarm is automatically cleared after the fault is rectified.