Configuring an Enhanced High-Speed NIC (Ubuntu)
This section uses Ubuntu 16.04 LTS (Xenial Xerus x86_64) as an example to describe how to bond enhanced high-speed NICs of a BMS.
The configuration methods of other Ubuntu OSs are similar to that of Ubuntu 16.04 LTS (Xenial Xerus x86_64).
Add a NIC
- Use a key or password to log in to the BMS as user root.
- On the BMS CLI, run the following command to check the NIC information:
ip link
Information similar to the following is displayed:
1: lo: <LOOPBACK,UP,LOWER_UP> mtu 65536 qdisc noqueue state UNKNOWN group default qlen 1 link/loopback 00:00:00:00:00:00 brd 00:00:00:00:00:00 inet 127.0.0.1/8 scope host lo valid_lft forever preferred_lft forever inet6 ::1/128 scope host valid_lft forever preferred_lft forever 2: eth0: <BROADCAST,MULTICAST,SLAVE,UP,LOWER_UP> mtu 8888 qdisc mq master bond0 state UP group default qlen 1000 link/ether fa:16:00:9b:91:c3 brd ff:ff:ff:ff:ff:ff 3: eth1: <BROADCAST,MULTICAST,SLAVE,UP,LOWER_UP> mtu 8888 qdisc mq master bond0 state UP group default qlen 1000 link/ether fa:16:00:9b:91:c3 brd ff:ff:ff:ff:ff:ff 4: p5p1: <BROADCAST,MULTICAST> mtu 1500 qdisc noop state DOWN group default qlen 1000 link/ether 40:7d:0f:52:e4:1d brd ff:ff:ff:ff:ff:ff 5: p5p2: <BROADCAST,MULTICAST> mtu 1500 qdisc noop state DOWN group default qlen 1000 link/ether 40:7d:0f:52:e4:1e brd ff:ff:ff:ff:ff:ff 6: p4p1: <BROADCAST,MULTICAST> mtu 1500 qdisc noop state DOWN group default qlen 1000 link/ether 40:7d:0f:52:e3:a9 brd ff:ff:ff:ff:ff:ff 7: p4p2: <BROADCAST,MULTICAST> mtu 1500 qdisc noop state DOWN group default qlen 1000 link/ether 40:7d:0f:52:e3:aa brd ff:ff:ff:ff:ff:ff 8: bond0: <BROADCAST,MULTICAST,MASTER,UP,LOWER_UP> mtu 8888 qdisc noqueue state UP group default qlen 1000 link/ether fa:16:00:9b:91:c3 brd ff:ff:ff:ff:ff:ff inet 192.168.254.85/24 brd 192.168.254.255 scope global bond0 valid_lft forever preferred_lft forever inet6 fe80::f816:ff:fe9b:91c3/64 scope link valid_lft forever preferred_lft forever 9: bond0.3157@bond0: <BROADCAST,MULTICAST,UP,LOWER_UP> mtu 8888 qdisc noqueue state UP group default qlen 1000 link/ether fa:16:00:9c:1e:79 brd ff:ff:ff:ff:ff:ff inet 192.168.100.14/24 brd 192.168.100.255 scope global bond0.3157 valid_lft forever preferred_lft forever inet6 fe80::f816:ff:fe9c:1e79/64 scope link valid_lft forever preferred_lft forever 10: bond0.3159@bond0: <BROADCAST,MULTICAST,UP,LOWER_UP> mtu 8888 qdisc noqueue state UP group default qlen 1000 link/ether fa:16:00:0a:2e:8e brd ff:ff:ff:ff:ff:ff inet 192.168.101.153/24 brd 192.168.101.255 scope global bond0.3159 valid_lft forever preferred_lft forever inet6 fe80::f816:ff:fe0a:2e8e/64 scope link valid_lft forever preferred_lft forever
eth0 and eth1 bear the VPC, and p5p1, p5p2, p4p1, and p4p2 bear the enhanced high-speed network. The following operations describe how to bond enhanced high-speed NICs p4p1 and p4p2.
- Run the following command to check whether the /etc/udev/rules.d/ directory contains the 80-persistent-net.rules file:
ll /etc/udev/rules.d/ | grep 80-persistent-net.rules
- Run the following command to copy the /etc/udev/rules.d/70-persistent-net.rules file and name the copy as /etc/udev/rules.d/80-persistent-net.rules.
cp -p /etc/udev/rules.d/70-persistent-net.rules /etc/udev/rules.d/80-persistent-net.rules
- Configure the udev rules:
Add the NICs and their MAC addresses obtained in step 2, except lo, eth0, eth1, and bond0, to the /etc/udev/rules.d/80-persistent-net.rules file. This ensures that the names and sequence of NICs will not change after the BMS is restarted.
Ensure that NIC MAC address and name are lowercase letters.
vim /etc/udev/rules.d/80-persistent-net.rules
The modification result is as follows:
SUBSYSTEM=="net", ACTION=="add", DRIVERS=="?*", ATTR{address}=="f4:4c:7f:5d:b6:fc", NAME="eth0" SUBSYSTEM=="net", ACTION=="add", DRIVERS=="?*", ATTR{address}=="f4:4c:7f:5d:b6:fd", NAME="eth1" SUBSYSTEM=="net", ACTION=="add", DRIVERS=="?*", ATTR{address}=="40:7d:0f:52:e4:1d", NAME="p5p1" SUBSYSTEM=="net", ACTION=="add", DRIVERS=="?*", ATTR{address}=="40:7d:0f:52:e4:1e", NAME="p5p2" SUBSYSTEM=="net", ACTION=="add", DRIVERS=="?*", ATTR{address}=="40:7d:0f:52:e3:a9", NAME="p4p1" SUBSYSTEM=="net", ACTION=="add", DRIVERS=="?*", ATTR{address}=="40:7d:0f:52:e3:aa", NAME="p4p2"
After the modification, press Esc, enter :wq, save the configuration, and exit.
- Run the following command to copy the /etc/network/interfaces.d/50-cloud-init.cfg file to generate the /etc/network/interfaces.d/60-cloud-init.cfg file:
cp -p /etc/network/interfaces.d/50-cloud-init.cfg /etc/network/interfaces.d/60-cloud-init.cfg
If the /etc/network/interfaces.d/50-cloud-init.cfg file does not exist, copy the /etc/network/interfaces file and run the following commands:
mkdir /etc/network/interfaces.d
cp -p /etc/network/interfaces /etc/network/interfaces.d/60-cloud-init.cfg
- Run the following command to edit the /etc/network/interfaces.d/60-cloud-init.cfg file of devices p4p1 and p4p2:
vim /etc/network/interfaces.d/60-cloud-init.cfg
Edit the file as follows:
auto p4p1 iface p4p1 inet manual bond_mode 1 bond-master bond1 bond_miimon 100 mtu 8888 auto p4p2 iface p4p2 inet manual bond_mode 1 bond-master bond1 bond_miimon 100 mtu 8888 auto bond1 iface bond1 inet static bond_miimon 100 bond-slaves none bond_mode 1 address 10.10.10.103 netmask 255.255.255.0 hwaddress 40:7d:0f:52:e3:a9 mtu 8888
Parameters are as follows:
- p4p1 and p4p2 are the names of the NICs that carry the enhanced high-speed network.
- hwaddress is the MAC address of p4p1.
- Change the value of address to the IP address allocated to enhanced high-speed network bond1. If the IP address planned for the enhanced high-speed network does not conflict with the VPC network segment, you can plan the IP address as needed, only to ensure that BMSs communicating through the enhanced high-speed network are in the same network segment as the enhanced high-speed network.
- Set the value of netmask to the subnet mask of the IP address configured for enhanced high-speed network bond1.
Set values of other parameters. For example, set mtu to 8888, bond_miimon to 100, and bond_mode to 1.
After the modification, press Esc, enter :wq, save the configuration, and exit.
- Run the following command to enable the bond NIC:
ifup p4p1
ifup p4p2
p4p1 and p4p2 are the NICs bearing the enhanced high-speed network.
- Run the following commands to check the NIC device status and whether the bond1 configuration file takes effect:
ip link
ifconfig
- Perform the preceding operations to configure other BMSs.
- After all BMSs are configured, ping the IP address in the same network segment as the enhanced high-speed network of other BMSs from each BMS.
For example, run the ping 10.10.10.102 command. The command output is as follows:
[root@bms-ubuntu ~]# ping 10.10.10.102 -I bond1 PING 10.10.10.102 (10.10.10.102) from 10.10.10.103 bond1: 56(84) bytes of data. 64 bytes from 10.10.10.102: icmp_seq=1 ttl=64 time=0.681 ms 64 bytes from 10.10.10.102: icmp_seq=2 ttl=64 time=0.035 ms 64 bytes from 10.10.10.102: icmp_seq=3 ttl=64 time=0.031 ms 64 bytes from 10.10.10.102: icmp_seq=4 ttl=64 time=0.030 ms ^C --- 10.10.10.102 ping statistics --- 4 packets transmitted, 4 received, 0% packet loss, time 3342ms
To configure a VLAN, perform the following steps:
- Configure the corresponding VLAN sub-interfaces based on the VLAN to be configured. Assuming that the VLAN ID is 316, run the following command to edit the /etc/network/interfaces.d/60-cloud-init.cfg file:
vim /etc/network/interfaces.d/60-cloud-init.cfg
Edit the file as follows:
auto p4p1 iface p4p1 inet manual bond_mode 1 bond-master bond1 bond_miimon 100 mtu 8888 auto p4p2 iface p4p2 inet manual bond_mode 1 bond-master bond1 bond_miimon 100 mtu 8888 auto bond1 iface bond1 inet static bond_miimon 100 bond-slaves none bond_mode 1 address 10.10.10.103 netmask 255.255.255.0 hwaddress 40:7d:0f:52:e3:a9 mtu 8888 auto bond1.316 iface bond1.316 inet static bond_miimon 100 bond-slaves none bond_mode 1 address 10.10.0.103 netmask 255.255.255.0 hwaddress 40:7d:0f:52:e3:a9 mtu 8888
- Run the following command to enable the VLAN sub-interface of the bond NIC:
ifup bond1.316
- After all BMSs are configured, ping the IP address in the same network segment as the enhanced high-speed network VLAN sub-interface of other BMSs from each BMS.
Delete a NIC
- Obtain the IP address of the bonded enhanced high-speed NIC to be deleted.
- Use a key or password to log in to the BMS as user root.
- Locate the bond network device and run the following command to stop and delete the device: If the bond has VLAN sub-interfaces, they will be automatically deleted.
[root@bms-ubuntu ~]# ifdown p4p1 [root@bms-ubuntu ~]# ifdown p4p2 [root@bms-ubuntu ~]# ifdown bond1
- Run the following command to delete network configuration file /etc/network/interfaces.d/60-cloud-init.cfg:
rm -f /etc/network/interfaces.d/60-cloud-init.cfg
Feedback
Was this page helpful?
Provide feedbackThank you very much for your feedback. We will continue working to improve the documentation.See the reply and handling status in My Cloud VOC.
For any further questions, feel free to contact us through the chatbot.