Model Warmup Is Abnormal or Partially Successful
During the model warmup process, issues such as warmup failures or partial success may occur. These typically manifest as model loading failures, response timeouts, or incomplete initialization of certain functions. In the event of a warmup failure, first verify that the model files are complete and not corrupted. Once the files are confirmed to be intact, check whether system resources, such as memory and CPU, are sufficient. If the warmup is only partially successful, it is recommended to refer to the corresponding error messages and take appropriate corrective actions based on the reported status.
Symptom
- The model warmup task is abnormal or partially successful.
- An error is reported when a warmup task is created or modified.
ModelArts.50015028 Invalid request body,XXX
ModelArts.50015029 Node binding cannot be disabled because ckpt warmup task exists in subpool XXX
ModelArts.50015030 node rebind should enable drain because ckpt warmup task exists in subpool XXX
ModelArts.50020100 Insufficient resource XXX
Possible Causes
| Status | Description | Solution |
|---|---|---|
| Warmup succeeded | The nodes in the resource pool have completed weight directory warmup. | No action is required. |
| Warming up | The nodes in the resource pool are warming up the weight directory. | No action is required. |
| No schedulable node | There is no schedulable node in the resource pool for weight directory warmup. As a result, the subtasks of the weight warmup task cannot be completed on the specified number of nodes. The possible causes are as follows: resource pool scale-in, node tainted, node fault, node draining, node restart, node logical subpool switchover, or insufficient node memory. | Check whether the number of available nodes in the resource pool is greater than the target number of nodes to be warmed up. The possible solutions to avoid no schedulable node are as follows:
|
| Warmup timeout | Weight warmup subtask timed out. | Check whether the size of the weight directory to be warmed up is too large or the download rate of the OBS image is too low. If the fault is not caused by the preceding reasons, contact O&M personnel for troubleshooting. |
| Insufficient memory | The actual size of the OBS directory selected when a weight warmup task is created is greater than the size of the space occupied by files set by you. | When creating a weight warmup task, set the space occupied by files to be greater than the actual size of the OBS directory. |
| Unknown error | The failure cause is not identified. | Possible causes: You have not granted the OBS Administrator permission to the ModelArts agency. As a result, the model warmup fails. Authorize the OBS Administrator permission to the ModelArts agency. If the fault is not caused by the preceding reasons, contact O&M personnel for troubleshooting. |
Solution
- If the model warmup is abnormal, rectify the fault based on the possible causes.