ALM-3276800137 Indicates that the stack set up failed
Description
FSP/3/SETUPFAILURE: OID [OID] Failed to set up a stack. (LocalSlotID=[integer], PeerSlotID=[integer], Reason=[STRING])
A stack fails to be set up.
Attribute
Alarm ID |
Alarm Severity |
Alarm Type |
---|---|---|
3276800137 |
Minor |
Communication alarm |
Parameters
Name |
Meaning |
---|---|
OID |
Indicates the MIB object ID of the alarm. |
LocalSlotID |
Indicates the slot ID of the local stack member switch. |
PeerSlotID |
Indicates the slot ID of the remote stack member switch. |
Reason |
Indicates the reason why the stack fails to be set up. |
Impact on the System
Services cannot run normally.
Possible Causes
- The switches cannot set up a stack because of a device model mismatch.
- The switches cannot set up a stack because ports on a dedicated stack card are connected to service ports.
Procedure
- Check whether ports on a dedicated stack card are connected to service ports on the panel or a service card.
- If so, change the connections.
- If not, go to step 2.
- Run the display device command to check the switch model.
- Use switches of the same model or different models that allow to set up a stack together based on Stack Configuration Notes.
Feedback
Was this page helpful?
Provide feedbackThank you very much for your feedback. We will continue working to improve the documentation.See the reply and handling status in My Cloud VOC.
For any further questions, feel free to contact us through the chatbot.