ALM-303046672 The PoE power module is abnormal
Description
POE/4/POEPWABSENT: OID [OID] POE Power is absent.(FrameID = [INTEGER], SlotID = [INTEGER])
An alarm is triggered when no PoE power supply on a PoE device is working properly.
Attribute
Alarm ID |
Alarm Severity |
Alarm Type |
---|---|---|
303046672 |
Warning |
Equipment alarm |
Parameters
Name |
Meaning |
---|---|
OID |
Indicates the MIB object ID of the alarm. |
FrameID |
Indicates the chassis ID of a device in a stack. |
SlotID |
Indicates the slot ID of the PoE power supply. |
Impact on the System
Services are not affected.
Possible Causes
No PoE power supply on the PoE device is working properly.
Procedure
- Run the display device command to check whether power modules of the PWR or PWH type are properly installed.
- If not, install a PoE power module. The alarm handling ends.
- If so, go to step 2.
- Run the display poe information command to check whether the power of the PoE power module is in the normal range.
- If so, collect alarm information and configuration information, and then contact technical support personnel.
- If not, replace this PoE power module.