Updated on 2024-01-25 GMT+08:00

ALM-135462998 hwCardFail

Description

ENTITYTRAP/2/CARDFAIL: OID [oid] Card fails. (Index=[INTEGER], EntityPhysicalIndex=[INTEGER], PhysicalName="[OCTET]", EntityTrapEntType=[INTEGER], EntityTrapFaultID=[INTEGER])

Some functions on a card fail.

Attribute

AlarmID

Alarm OID

Alarm Severity

Alarm Type

135462998

1.3.6.1.4.1.2011.5.25.219.2.3.3

Critical

Equipment alarm

Parameters

Name

Meaning

oid

Indicates the MIB object ID of the alarm.

Index

Indicates the alarm index.

EntityPhysicalIndex

Indicates the physical entity index.

PhysicalName

Indicates the name of the physical entity where the alarm is generated.

EntityTrapEntType

Indicates the alarm type.

EntityTrapFaultID

Indicates the error code of the alarm, which is 135194.

Impact on the System

The IIC bus cannot be accessed normally.

Possible Causes

The IIC bus has failed.

Procedure

  • Remove and install the card and then check whether the alarm is cleared.
    • If so, the alarm handling ends.
    • If not, go to step 2.
  • Replace the card and check whether the alarm is cleared.
    • If so, the alarm handling ends.
    • If not, collect alarm information and configuration information, and then contact technical support personnel.

Related Information