Help Center/ MapReduce Service/ User Guide/ MRS Manager Operation Guide (Applicable to 2.x and Earlier Versions)/ Alarm Reference (Applicable to MRS 2.x and Earlier Versions)/ ALM-43011 Non-Heap Memory Usage of the JDBCServer Process Exceeds the Threshold (For MRS 2.x or Earlier)
Updated on 2024-04-11 GMT+08:00

ALM-43011 Non-Heap Memory Usage of the JDBCServer Process Exceeds the Threshold (For MRS 2.x or Earlier)

Description

The system checks the JDBCServer process status every 30 seconds. The alarm is generated when the non-heap memory usage of the JDBCServer process exceeds the threshold (90% of the maximum memory).

Attribute

Alarm ID

Alarm Severity

Automatically Cleared

43011

Major

Yes

Parameters

Parameter

Description

ServiceName

Specifies the service for which the alarm is generated.

RoleName

Specifies the role for which the alarm is generated.

HostName

Specifies the host for which the alarm is generated.

Impact on the System

If the available JDBCServer process non-heap memory is insufficient, a memory overflow occurs and the service breaks down.

Possible Causes

The non-heap memory of the JDBCServer process is overused or the non-heap memory is inappropriately allocated.

Procedure

  1. Check non-heap memory usage.

    1. Go to the cluster details page and choose Alarms.
    2. Select the alarm whose Alarm ID is 43011 and view the IP address and role name of the instance in Location.
    3. Choose Components > Spark > Instance > JDBCServer (IP address of the instance for which the alarm is generated) > Customize > Non-heap Memory Statistics of the JDBCServer Process. Click OK to view the non-heap memory usage.
    4. Check whether the non-heap memory usage of JDBCServer has reached the threshold (90% of the maximum non-heap memory).
      • If yes, go to 1.e.
      • If no, go to 2.
    5. Choose Components > Spark > Service Configuration. Set Type to All and choose JDBCServer > Tuning. Increase the value of -XX:MaxMetaspaceSize in spark.driver.extraJavaOptions as required.
    6. Check whether the alarm is cleared.
      • If yes, no further action is required.
      • If no, go to 2.

  2. Collect fault information.

    1. On MRS Manager, choose System > Export Log.
    2. Contact the O&M engineers and send the collected logs.

Reference