ALM-12011 Data Synchronization Exception Between the Active and Standby Manager Nodes (For MRS 2.x or Earlier)
Description
This alarm is generated when the standby Manager fails to synchronize files with the active Manager.
This alarm is cleared when the standby Manager synchronizes files with the active Manager.
Attribute
Alarm ID |
Alarm Severity |
Auto Clear |
---|---|---|
12011 |
Critical |
Yes |
Parameters
Parameter |
Description |
---|---|
ServiceName |
Specifies the service for which the alarm is generated. |
RoleName |
Specifies the role for which the alarm is generated. |
HostName |
Specifies the host for which the alarm is generated. |
Local Manager HA Name |
Specifies a local Manager HA. |
Peer Manager HA Name |
Specifies a peer Manager HA. |
Impact on the System
Because the configuration files on the standby Manager are not updated, some configurations will be lost after an active/standby switchover. Manager and some components may not run properly.
Possible Causes
The link between the active and standby Manager nodes is interrupted.
Procedure
- Check whether the network between the active and standby Manager servers is normal.
- Go to the MRS cluster details page. In the alarm list on the alarm management tab page, click the row that contains the alarm. In the alarm details, view the address of the standby Manager server.
- Log in to the active management node. Run the following command to check whether the standby Manager is reachable:
- Contact the O&M personnel to check whether the network is faulty.
- Rectify the network fault and check whether the alarm is cleared from the alarm list.
- If yes, no further action is required.
- If no, go to 2.
- Collect fault information.
- On MRS Manager, choose .
- Contact the O&M engineers and send the collected logs.
Reference
None