ALM-45742 Failed to Call the ECS Metadata API
This section applies only to MRS 3.1.5 or later.
Alarm Description
When Guardian calls an IAM API to obtain the temporary AK/SK, it needs to first obtain related metadata via the ECS Metadata API. This alarm is generated when Guardian fails to call the Metadata API.
Alarm Attributes
Alarm ID |
Alarm Severity |
Auto Cleared |
---|---|---|
45742 |
Major |
Yes |
Alarm Parameters
Parameter |
Description |
---|---|
Source |
Specifies the cluster for which the alarm was generated. |
ServiceName |
Specifies the service for which the alarm was generated. |
RoleName |
Specifies the role for which the alarm was generated. |
HostName |
Specifies the host for which the alarm was generated. |
Impact on the System
The task may fail to obtain the temporary AK/SK for accessing OBS. As a result, the task cannot access OBS.
Possible Causes
An underlying interface of ECS is abnormal.
Handling Procedure
Collect fault information.
- On FusionInsight Manager, choose O&M. In the navigation pane on the left, choose Log > Download.
- Expand the Service drop-down list, and select Guardian for the target cluster.
- Click in the upper right corner, and set Start Date and End Date for log collection to 1 hour ahead of and after the alarm generation time, respectively. Then, click Download.
- Contact O&M personnel and provide the collected logs.
Alarm Clearance
This alarm is automatically cleared after the fault is rectified.
Related Information
None
Feedback
Was this page helpful?
Provide feedbackThank you very much for your feedback. We will continue working to improve the documentation.