Help Center/ MapReduce Service/ User Guide/ Alarm Reference (Applicable to MRS 3.x)/ ALM-45636 FlinkServer Job Checkpoints Keep Failing
Updated on 2024-04-11 GMT+08:00

ALM-45636 FlinkServer Job Checkpoints Keep Failing

This section applies to MRS 3.1.2 or a version between 3.1.2 and 3.2.0.

Alarm Description

The system checks the number of consecutive checkpoint failures based on the configured alarm checking interval. This alarm is generated when the number of consecutive checkpoint failures of a FlinkServer job reaches the configured threshold. This alarm is cleared when checkpoints are recovered or the job is successfully restarted.

Alarm Attributes

Alarm ID

Alarm Severity

Auto Cleared

45636

Minor

Yes

Alarm Parameters

Parameter

Description

Source

Specifies the cluster for which the alarm was generated.

ServiceName

Specifies the service for which the alarm was generated.

JobName

Specifies the job for which the alarm was generated.

Impact on the System

This alarm has no impact on the system.

Possible Causes

You can view failure causes in specific logs.

Handling Procedure

  1. Log in to Manager as a user who has the FlinkServer management permission.
  2. Choose Cluster > Services > Yarn and click the link next to ResourceManager WebUI to go to the Yarn page.
  3. Locate the failed job based on its name displayed in Location, search for and record the application ID of the failed job, and check whether the job logs are available on the Yarn page.

    Figure 1 Application ID of a job

    If yes, go to 4.

    If no, go to 6.

  4. Click the application ID of the failed job to go to the job page.

    1. Click Logs in the Logs column to view JobManager logs.
      Figure 2 Clicking Logs
    2. Click the ID in the Attempt ID column and click Logs in the Logs column to view TaskManager logs.
      Figure 3 Clicking the ID in the Attempt ID column
      Figure 4 Clicking Logs

      You can also log in to Manager as a user who has the FlinkServer management permission, choose Cluster > Services > Flink, click the link next to Flink WebUI. On the displayed Flink web UI, click Job Management and choose More > Job Monitoring in the Operation column to view the TaskManager logs.

  5. View the logs of the failed job to rectify the fault, or contact the O&M personnel personnel and send the collected fault logs. No further action is required.

If logs are unavailable on the Yarn page, download logs from HDFS.

  1. On Manager, choose Cluster > Services > HDFS, click the link next to NameNode WebUI to go to the HDFS page, select Utilities > Browse the file system, and download logs in the /tmp/logs/User name/logs/Application ID of the failed job directory.
  2. View the logs of the failed job to rectify the fault, or contact the O&M personnel personnel and send the collected fault logs.

Alarm Clearance

This alarm is cleared when FlinkServer job checkpoints are recovered or the job is successfully restarted.

Related Information

None