Help Center/ MapReduce Service/ User Guide/ Alarm Reference (Applicable to MRS 3.x)/ ALM-45592 IoTDBServer RPC Execution Duration Exceeds the Threshold
Updated on 2024-04-11 GMT+08:00

ALM-45592 IoTDBServer RPC Execution Duration Exceeds the Threshold

Alarm Description

The system checks the RPC execution duration of the IoTDBServer process every 60 seconds. This alarm is generated when the execution duration exceeds the threshold. This alarm is cleared when the RPC execution time of the IoTDBServer process is less than the threshold.

Alarm Attributes

Alarm ID

Alarm Severity

Auto Cleared

45592

Major

Yes

Alarm Parameters

Parameter

Description

Source

Specifies the cluster for which the alarm was generated.

ServiceName

Specifies the service for which the alarm was generated.

RoleName

Specifies the role for which the alarm was generated.

HostName

Specifies the host for which the alarm was generated.

Impact on the System

Running performance of the IoTDBServer process is affected.

Possible Causes

The processing duration of an IoTDBServer RPC request exceeds the threshold. Logs need to be further analyzed to locate the cause.

Handling Procedure

Collect fault information.

  1. Log in to FusionInsight Manager and choose O&M > Alarm > Alarms. In the real-time alarm list, click in front of this alarm and view the role name and instance IP address in Location.
  2. Choose O&M > Log > Download.
  3. Expand the Service drop-down list, select IoTDB for the target cluster, and click OK.
  4. Expand the Hosts drop-down list. In the Select Host dialog box that is displayed, select the host queried in 1, and click OK.
  5. Click in the upper right corner, and set Start Date and End Date for log collection to 30 minutes ahead of and after the alarm generation time respectively. Then, click Download.
  6. Contact O&M personnel and provide the collected logs.

Alarm Clearance

This alarm is automatically cleared after the fault is rectified.

Related Information

None